We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.
We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.
Spontaneous sealing of a type Ia endoleak after ovation stent graft implantation in a patient with on-label aortic neck anatomy / Pranteda, Chiara; Sirignano, Pasqualino; Capoccia, Laura; Mansour, WASSIM AHMAD; Montelione, Nunzio; Speziale, Francesco. - In: ANNALS OF VASCULAR SURGERY. - ISSN 0890-5096. - STAMPA. - 34:270(2016), pp. e19-e24. [10.1016/j.avsg.2015.12.012]
Spontaneous sealing of a type Ia endoleak after ovation stent graft implantation in a patient with on-label aortic neck anatomy
PRANTEDA, CHIARA
;SIRIGNANO, PASQUALINO;CAPOCCIA, LAURA;MANSOUR, WASSIM AHMAD;MONTELIONE, NUNZIO;SPEZIALE, Francesco
2016
Abstract
We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.File | Dimensione | Formato | |
---|---|---|---|
Pranteda_Endoleak_2016.pdf
accesso aperto
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
584.45 kB
Formato
Adobe PDF
|
584.45 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.