Consider a differential-drive mobile robot equipped with an on-board exteroceptive sensor that can estimate its own motion, e. g., a range-finder. Calibration of this robot involves estimating six parameters: three for the odometry (radii and distance between the wheels) and three for the pose of the sensor with respect to the robot. After analyzing the observability of this problem, this paper describes a method for calibrating all parameters at the same time, without the need for external sensors or devices, using only the measurement of the wheel velocities and the data from the exteroceptive sensor. The method does not require the robot to move along particular trajectories. Simultaneous calibration is formulated as a maximum-likelihood problem and the solution is found in a closed form. Experimental results show that the accuracy of the proposed calibration method is very close to the attainable limit given by the Cramer-Rao bound.

Simultaneous Calibration of Odometry and Sensor Parameters for Mobile Robots / Censi, Andrea; Franchi, Antonio; Marchionni, Luca; Oriolo, Giuseppe. - In: IEEE TRANSACTIONS ON ROBOTICS. - ISSN 1552-3098. - STAMPA. - 29:2(2013), pp. 475-492. [10.1109/tro.2012.2226380]

Simultaneous Calibration of Odometry and Sensor Parameters for Mobile Robots

FRANCHI, ANTONIO;ORIOLO, Giuseppe
2013

Abstract

Consider a differential-drive mobile robot equipped with an on-board exteroceptive sensor that can estimate its own motion, e. g., a range-finder. Calibration of this robot involves estimating six parameters: three for the odometry (radii and distance between the wheels) and three for the pose of the sensor with respect to the robot. After analyzing the observability of this problem, this paper describes a method for calibrating all parameters at the same time, without the need for external sensors or devices, using only the measurement of the wheel velocities and the data from the exteroceptive sensor. The method does not require the robot to move along particular trajectories. Simultaneous calibration is formulated as a maximum-likelihood problem and the solution is found in a closed form. Experimental results show that the accuracy of the proposed calibration method is very close to the attainable limit given by the Cramer-Rao bound.
2013
differential-drive; extrinsic calibration; mobile robots; odometry calibration
01 Pubblicazione su rivista::01a Articolo in rivista
Simultaneous Calibration of Odometry and Sensor Parameters for Mobile Robots / Censi, Andrea; Franchi, Antonio; Marchionni, Luca; Oriolo, Giuseppe. - In: IEEE TRANSACTIONS ON ROBOTICS. - ISSN 1552-3098. - STAMPA. - 29:2(2013), pp. 475-492. [10.1109/tro.2012.2226380]
File allegati a questo prodotto
File Dimensione Formato  
VE_2013_11573-495656.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.18 MB
Formato Adobe PDF
1.18 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/495656
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 106
  • ???jsp.display-item.citation.isi??? 86
social impact