Background: Real life data on adverse events of penile prosthesis are lacking. Aim of this study is to summarize medical device reports (MDRs) related to penile prosthesis implants within the Manufacturer and User Facility Device Experience (MAUDE) database held by The Food and Drug Administration (FDA). Methods: We examined all MDRs from MAUDE database reported in the last ten years related to each FDA-approved penile implant. Event descriptions were reviewed and classified into specific event types. Outcome measures included specific penile prosthesis and reported events as detailed by the MDRs. All data is in line with the Health Insurance Portability and Accountability Act (HIPAA). Pooled Relative risk was used to compare data. Results: Overall, in 10 years, 1340 reports were sent, with the highest number of events reported between 2019 and 2022. Overall, 1240/1340 (92%) were reported as injury while 91/1340 (7%) as implant malfunction. Infection (181/1340: 14%), Erosion (144/1340: 11%), Pain (68/1340: 5%) and Perforation (47/1340: 4%) were the most frequently reported adverse events (AEs). In terms of manufacturer: 675/1340 (50%) were from Boston Scientific, 198/1340 (15%) were Coloplast and 463/1340 (35%) were AMS. When comparing different producers on disproportional analysis, Coloplast presented a higher risk of infection when compared to Boston Scientific and AMS (PRR= 1.5-2.62; P<0.05). Perforation, pain, failure to implant and erosion incidence were comparable between manufacturers. Conclusions: According to MAUDE database, the most frequent complications related to penile prosthesis are infections, erosions, pain, and perforation. Coloplast prosthesis seem to be associated with a higher risk of infection.

Trends and incidence of postoperative reported events associated with penile prosthesis. An analysis of the food and drug administration's manufacturer and user facility device experience database / Lombardo, Riccardo; Zammitti, Filippo; Nacchia, Antonio; Guercio, Alessandro; Turchi, Beatrice; Romagnoli, Matteo; Santoro, Giuseppe; Franco, Antonio; Tema, Giorgia; Cicione, Antonio; Fuschi, Andrea; Al Salhi, Yazan; Pastore, Antonio L.; Tubaro, Andrea; De Nunzio, Cosimo. - In: MINERVA UROLOGY AND NEPHROLOGY. - ISSN 2724-6442. - (2025).

Trends and incidence of postoperative reported events associated with penile prosthesis. An analysis of the food and drug administration's manufacturer and user facility device experience database

Riccardo LOMBARDO;Filippo ZAMMITTI;Antonio NACCHIA;Alessandro GUERCIO;Beatrice TURCHI;Matteo ROMAGNOLI;Giuseppe SANTORO;Antonio FRANCO;Giorgia TEMA;Antonio CICIONE;Andrea FUSCHI;Yazan AL SALHI;Antonio L. PASTORE;Andrea TUBARO;Cosimo DE NUNZIO
2025

Abstract

Background: Real life data on adverse events of penile prosthesis are lacking. Aim of this study is to summarize medical device reports (MDRs) related to penile prosthesis implants within the Manufacturer and User Facility Device Experience (MAUDE) database held by The Food and Drug Administration (FDA). Methods: We examined all MDRs from MAUDE database reported in the last ten years related to each FDA-approved penile implant. Event descriptions were reviewed and classified into specific event types. Outcome measures included specific penile prosthesis and reported events as detailed by the MDRs. All data is in line with the Health Insurance Portability and Accountability Act (HIPAA). Pooled Relative risk was used to compare data. Results: Overall, in 10 years, 1340 reports were sent, with the highest number of events reported between 2019 and 2022. Overall, 1240/1340 (92%) were reported as injury while 91/1340 (7%) as implant malfunction. Infection (181/1340: 14%), Erosion (144/1340: 11%), Pain (68/1340: 5%) and Perforation (47/1340: 4%) were the most frequently reported adverse events (AEs). In terms of manufacturer: 675/1340 (50%) were from Boston Scientific, 198/1340 (15%) were Coloplast and 463/1340 (35%) were AMS. When comparing different producers on disproportional analysis, Coloplast presented a higher risk of infection when compared to Boston Scientific and AMS (PRR= 1.5-2.62; P<0.05). Perforation, pain, failure to implant and erosion incidence were comparable between manufacturers. Conclusions: According to MAUDE database, the most frequent complications related to penile prosthesis are infections, erosions, pain, and perforation. Coloplast prosthesis seem to be associated with a higher risk of infection.
2025
Penile prosthesis; Erectile dysfunction; Database; Infections
01 Pubblicazione su rivista::01a Articolo in rivista
Trends and incidence of postoperative reported events associated with penile prosthesis. An analysis of the food and drug administration's manufacturer and user facility device experience database / Lombardo, Riccardo; Zammitti, Filippo; Nacchia, Antonio; Guercio, Alessandro; Turchi, Beatrice; Romagnoli, Matteo; Santoro, Giuseppe; Franco, Antonio; Tema, Giorgia; Cicione, Antonio; Fuschi, Andrea; Al Salhi, Yazan; Pastore, Antonio L.; Tubaro, Andrea; De Nunzio, Cosimo. - In: MINERVA UROLOGY AND NEPHROLOGY. - ISSN 2724-6442. - (2025).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1753483
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact