A direct reversed-phase high-performance liquid chromatographic (HPLC) method was developed for deter-mining the content of the enantiomeric impurity of the chiral statin rosuvastatin calcium salt (RSV) in com-mercial tablets. The baseline enantioseparation was achieved using the Lux Cellulose-2 column and a binary linear gradient of acetonitrile and trifluoroacetic acid 0.05% in an aqueous solution. The flow rate of the mobile phases and column temperature were set at 1.0 mL min- 1 and 40 degrees C, respectively. In comparison with the isocratic HPLC method reported in the European Pharmacopoeia (EP) monograph for RSV, the gradient elution method offered improved chemo-and enantio-selectivity and reduced analysis times. The limits of quantitation and detection of the enantiomeric impurity were found to be 0.15 and 0.05 mu g mL-1.
Chemo- and enantio-selective reversed-phase HPLC analysis of rosuvastatin using a cellulose-based chiral stationary phase in gradient elution mode / Mammone, FRANCESCA ROMANA; Rotundo, Paola; Ferretti, Rosella; Puxeddu, Michela; Silvestri, Romano; Cirilli, Roberto. - In: JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS. - ISSN 0731-7085. - 225:(2023), pp. 1-6. [10.1016/j.jpba.2023.115239]
Chemo- and enantio-selective reversed-phase HPLC analysis of rosuvastatin using a cellulose-based chiral stationary phase in gradient elution mode
Francesca Romana Mammone;Paola Rotundo;Michela Puxeddu;Romano Silvestri;
2023
Abstract
A direct reversed-phase high-performance liquid chromatographic (HPLC) method was developed for deter-mining the content of the enantiomeric impurity of the chiral statin rosuvastatin calcium salt (RSV) in com-mercial tablets. The baseline enantioseparation was achieved using the Lux Cellulose-2 column and a binary linear gradient of acetonitrile and trifluoroacetic acid 0.05% in an aqueous solution. The flow rate of the mobile phases and column temperature were set at 1.0 mL min- 1 and 40 degrees C, respectively. In comparison with the isocratic HPLC method reported in the European Pharmacopoeia (EP) monograph for RSV, the gradient elution method offered improved chemo-and enantio-selectivity and reduced analysis times. The limits of quantitation and detection of the enantiomeric impurity were found to be 0.15 and 0.05 mu g mL-1.File | Dimensione | Formato | |
---|---|---|---|
Mammone_Chemo-and-enantio-selective_2023.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.92 MB
Formato
Adobe PDF
|
1.92 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.