A fast HPLC method with fluorescence detector (FD) was developed for the determination of three tocopherols (TOCs) in milk samples from Modicana cattle breed. The ultrasound-assisted procedure was optimized for the extraction of TOCs prior to HPLC/FD analysis, reducing sample preparation time and allowing a fast quantification of α-tocopherol, δ-tocopherol and γ tocopherol. The optimized ultrasonic extraction combines an efficient and simple saponification at room temperature and a rapid HPLC quantification of TOCs in milk. The precision of the full analytical procedure was satisfactory and the recoveries at three spiked levels were between 95.3% and 87.8%. The linear correlations were evaluated (R2 > 0.99) and the relative standard deviation (RSD) values for intra-day and inter-day tests at three spiked levels were below 1% for the retention time and below 5.20% for the area at low level spiking. The proposed procedure, reducing the experimental complexity, allowed accurate extraction and detection of three TOCs in milk samples from Modicana cattle breed.
A fast and efficient ultrasound-assisted extraction of tocopherols in cow milk followed by hplc determination / Rotondo, A.; La Torre, G. L.; Gervasi, T.; Di Matteo, G.; Spano, M.; Ingallina, C.; Salvo, A.. - In: MOLECULES. - ISSN 1420-3049. - 26:15(2021), pp. 1-12. [10.3390/molecules26154645]
A fast and efficient ultrasound-assisted extraction of tocopherols in cow milk followed by hplc determination
Di Matteo G.Formal Analysis
;Spano M.Formal Analysis
;Ingallina C.Formal Analysis
;Salvo A.
Project Administration
2021
Abstract
A fast HPLC method with fluorescence detector (FD) was developed for the determination of three tocopherols (TOCs) in milk samples from Modicana cattle breed. The ultrasound-assisted procedure was optimized for the extraction of TOCs prior to HPLC/FD analysis, reducing sample preparation time and allowing a fast quantification of α-tocopherol, δ-tocopherol and γ tocopherol. The optimized ultrasonic extraction combines an efficient and simple saponification at room temperature and a rapid HPLC quantification of TOCs in milk. The precision of the full analytical procedure was satisfactory and the recoveries at three spiked levels were between 95.3% and 87.8%. The linear correlations were evaluated (R2 > 0.99) and the relative standard deviation (RSD) values for intra-day and inter-day tests at three spiked levels were below 1% for the retention time and below 5.20% for the area at low level spiking. The proposed procedure, reducing the experimental complexity, allowed accurate extraction and detection of three TOCs in milk samples from Modicana cattle breed.File | Dimensione | Formato | |
---|---|---|---|
Rotondo_fast-efficient_2021.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
1.24 MB
Formato
Adobe PDF
|
1.24 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.