This contribution describes the irradiation set-up for electronic and space components testing with pulsed 30 MeV proton beam of high instantaneous dose rate provided by the TOP-IMPLART linear accelerator at ENEA Frascati Research Centre.

Dosimetric characterization of an irradiation set-up for electronic components testing at the TOP-IMPLART proton linear accelerator / Bazzano, G.; Ampollini, A.; Blasi, L.; Cardelli, F.; Cisbani, E.; De Angelis, C.; Delle Monache, S.; Mastrandrea, A.; Menichelli, F.; Nenzi, P.; Olivieri, M.; Palmerini, G. B.; Picardi, L.; Piccinini, M.; Ronsivalle, C.; Sabatini, M.; Vigli, F.. - (2019), pp. 1-4. (Intervento presentato al convegno 2019 19th European conference on radiation and its effects on components and systems, RADECS 2019 tenutosi a Montpellier; France) [10.1109/RADECS47380.2019.9745701].

Dosimetric characterization of an irradiation set-up for electronic components testing at the TOP-IMPLART proton linear accelerator

G. Bazzano
Primo
;
L. Blasi;F. Cardelli;A. Mastrandrea;F. Menichelli;P. Nenzi;M. Olivieri;G. B. Palmerini;M. Sabatini;F. Vigli
2019

Abstract

This contribution describes the irradiation set-up for electronic and space components testing with pulsed 30 MeV proton beam of high instantaneous dose rate provided by the TOP-IMPLART linear accelerator at ENEA Frascati Research Centre.
2019
2019 19th European conference on radiation and its effects on components and systems, RADECS 2019
dosimetry; linear accelerator; radiation test
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Dosimetric characterization of an irradiation set-up for electronic components testing at the TOP-IMPLART proton linear accelerator / Bazzano, G.; Ampollini, A.; Blasi, L.; Cardelli, F.; Cisbani, E.; De Angelis, C.; Delle Monache, S.; Mastrandrea, A.; Menichelli, F.; Nenzi, P.; Olivieri, M.; Palmerini, G. B.; Picardi, L.; Piccinini, M.; Ronsivalle, C.; Sabatini, M.; Vigli, F.. - (2019), pp. 1-4. (Intervento presentato al convegno 2019 19th European conference on radiation and its effects on components and systems, RADECS 2019 tenutosi a Montpellier; France) [10.1109/RADECS47380.2019.9745701].
File allegati a questo prodotto
File Dimensione Formato  
Bazzano_Dosimetric characterization_2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 548.67 kB
Formato Adobe PDF
548.67 kB Adobe PDF   Contatta l'autore