This paper proposes an approach for displaying the needle-tip interaction force exchanged between the needle tip and the tissues to the remote operator of a teleoperated needle insertion procedure. As known, the measures of the needle tip interaction force with tissues obtained through F/T sensor at the robot wrist do not provide a transparent perception of the needle-tissue interaction at the tip mainly because of the friction between the needle shaft and the traversed tissues. Current literature mainly proposes hardware solutions to the problem of measuring the forces at the needle tip. In this work we aim instead at cleaning the F/T sensor information for rendering only the estimated force exchanged at the needle tip. The approach is based on an online identification of the parameters of a needle-tissue interaction force model to isolate offset force values mainly due to friction. The approach, validated through simulations and experiments, is expected to increase the sensitivity of the rendered force to tissue transitions thus improving safety and accuracy in needle placement.

Enhancing force feedback in teleoperated needle insertion through on-line identification of the needle-tissue interaction parameters / N., Cacciotti; A., Cifonelli; Gaz, CLAUDIO ROBERTO; V., Paduano; A. V., Russo; Vendittelli, Marilena. - ELETTRONICO. - (2018), pp. 79-85. ( 7th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, BIOROB 2018 Enschede; Netherlands ) [10.1109/BIOROB.2018.8487952].

Enhancing force feedback in teleoperated needle insertion through on-line identification of the needle-tissue interaction parameters

GAZ, CLAUDIO ROBERTO
Membro del Collaboration Group
;
VENDITTELLI, Marilena
Membro del Collaboration Group
2018

Abstract

This paper proposes an approach for displaying the needle-tip interaction force exchanged between the needle tip and the tissues to the remote operator of a teleoperated needle insertion procedure. As known, the measures of the needle tip interaction force with tissues obtained through F/T sensor at the robot wrist do not provide a transparent perception of the needle-tissue interaction at the tip mainly because of the friction between the needle shaft and the traversed tissues. Current literature mainly proposes hardware solutions to the problem of measuring the forces at the needle tip. In this work we aim instead at cleaning the F/T sensor information for rendering only the estimated force exchanged at the needle tip. The approach is based on an online identification of the parameters of a needle-tissue interaction force model to isolate offset force values mainly due to friction. The approach, validated through simulations and experiments, is expected to increase the sensitivity of the rendered force to tissue transitions thus improving safety and accuracy in needle placement.
2018
7th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, BIOROB 2018
identification; needle-tissue interaction force estimation; teleoperation; medical robotics;
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Enhancing force feedback in teleoperated needle insertion through on-line identification of the needle-tissue interaction parameters / N., Cacciotti; A., Cifonelli; Gaz, CLAUDIO ROBERTO; V., Paduano; A. V., Russo; Vendittelli, Marilena. - ELETTRONICO. - (2018), pp. 79-85. ( 7th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics, BIOROB 2018 Enschede; Netherlands ) [10.1109/BIOROB.2018.8487952].
File allegati a questo prodotto
File Dimensione Formato  
Cacciotti_Enhancing_2018.pdf

solo gestori archivio

Note: file dai proceedings elettronici della conferenza
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 708.57 kB
Formato Adobe PDF
708.57 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1137867
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact