Thoracic endovascular aortic repair (TEVAR) is a less invasive option for managing traumatic injuries of the descending aorta in polytraumatized patients. Concerns arise when treating young patients with TEVAR. A 22-year-old male was admitted to the emergency department following a high-impact road traffic collision. Whole-body computed tomography (CT) scan documented multiple injuries, including rupture of descending thoracic aorta just below the isthmus. There was no evidence of paraplegia or stroke. We decided to treat him in an endovascular fashion with a Zenith Cook (Cook Incorporated, Bloomington, IN) endograft. Final angiography confirmed the proper positioning of the device, no infoldings, and the optimal filling of the thoracic aorta downstream of the endoprosthesis. In the postoperative period, the patient showed high blood pressure which was treated with 4 different antihypertensive drugs. He was discharged on cardioaspirine. CT scan control was scheduled after 30 days and 6 months, but he referred to our emergency department after less than 6 months with paraplegia, abdominal pain, and acute renal failure. He had independently discontinued antiplatelet therapy 3 months before. Emergency CT control documented the presence of intimal flap and thrombus at the distal edge of the device. The magnetic resonance imaging revealed ischemic damage of the spinal cord. We decided to reline the endograft using another Zenith Cook device with very good results. Renal failure and bowel pain gradually improved, but paraplegia is still present. TEVAR is the most suitable treatment for blunt thoracic aortic injury in the modern era. Concerns arise from what can happen to a young aorta receiving a stiff endovascular graft that should be carried all lifelong. These devices have been associated with acute hypertension and cardiac remodeling. Less stiffer stent grafts should be studied for young patients. High attention must be posed in the follow-up for the immediate resolution of eventual problems.

Hypertension, acute stent thrombosis, and paraplegia 6 months after thoracic endovascular aortic repair for blunt thoracic aortic injury in a 22-year-old patient / Martinelli, Ombretta; Faccenna, Federico; Malaj, Alban; Jabbour, Jihad; Venosi, Salvatore; Gattuso, Roberto; Gossetti, Bruno; Irace, Luigi. - In: ANNALS OF VASCULAR SURGERY. - ISSN 0890-5096. - 47:(2018), pp. 281 e5-281 e10. [10.1016/j.avsg.2017.08.041]

Hypertension, acute stent thrombosis, and paraplegia 6 months after thoracic endovascular aortic repair for blunt thoracic aortic injury in a 22-year-old patient

Martinelli, Ombretta;Venosi, Salvatore;Gattuso, Roberto;Gossetti, Bruno;Irace, Luigi
2018

Abstract

Thoracic endovascular aortic repair (TEVAR) is a less invasive option for managing traumatic injuries of the descending aorta in polytraumatized patients. Concerns arise when treating young patients with TEVAR. A 22-year-old male was admitted to the emergency department following a high-impact road traffic collision. Whole-body computed tomography (CT) scan documented multiple injuries, including rupture of descending thoracic aorta just below the isthmus. There was no evidence of paraplegia or stroke. We decided to treat him in an endovascular fashion with a Zenith Cook (Cook Incorporated, Bloomington, IN) endograft. Final angiography confirmed the proper positioning of the device, no infoldings, and the optimal filling of the thoracic aorta downstream of the endoprosthesis. In the postoperative period, the patient showed high blood pressure which was treated with 4 different antihypertensive drugs. He was discharged on cardioaspirine. CT scan control was scheduled after 30 days and 6 months, but he referred to our emergency department after less than 6 months with paraplegia, abdominal pain, and acute renal failure. He had independently discontinued antiplatelet therapy 3 months before. Emergency CT control documented the presence of intimal flap and thrombus at the distal edge of the device. The magnetic resonance imaging revealed ischemic damage of the spinal cord. We decided to reline the endograft using another Zenith Cook device with very good results. Renal failure and bowel pain gradually improved, but paraplegia is still present. TEVAR is the most suitable treatment for blunt thoracic aortic injury in the modern era. Concerns arise from what can happen to a young aorta receiving a stiff endovascular graft that should be carried all lifelong. These devices have been associated with acute hypertension and cardiac remodeling. Less stiffer stent grafts should be studied for young patients. High attention must be posed in the follow-up for the immediate resolution of eventual problems.
2018
Surgery; Cardiology and Cardiovascular Medicine; aneurism
01 Pubblicazione su rivista::01i Case report
Hypertension, acute stent thrombosis, and paraplegia 6 months after thoracic endovascular aortic repair for blunt thoracic aortic injury in a 22-year-old patient / Martinelli, Ombretta; Faccenna, Federico; Malaj, Alban; Jabbour, Jihad; Venosi, Salvatore; Gattuso, Roberto; Gossetti, Bruno; Irace, Luigi. - In: ANNALS OF VASCULAR SURGERY. - ISSN 0890-5096. - 47:(2018), pp. 281 e5-281 e10. [10.1016/j.avsg.2017.08.041]
File allegati a questo prodotto
File Dimensione Formato  
Martinelli_Hypertension-thrombosis-paraplegia_2018.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 5.94 MB
Formato Adobe PDF
5.94 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1061054
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact