The aim of this pilot study is to test the feasibility and effectiveness of a wearable proprioceptive stabilizer that emits focal mechanical vibrations in patients affected by hereditary cerebellar ataxias. Eleven adult patients with a confirmed genetic diagnosis of autosomal dominant spinocerebellar ataxia or Friedreich's ataxia were asked to wear an active device for 3 weeks. Assessments were performed at baseline, after the device use (T1), and 3 weeks after (T2). SARA, 9-HPT, PATA, 6MWT, and spatial and temporal gait parameters, measured with a BTS-G-Walk inertial sensor, were used as study endpoints. As expected, no adverse effects were reported. Statistically significant improvements in SARA, 9HPT dominant hand, PATA test, 6MWT, cadence, length cycle, support right/cycle, support left/cycle, flight right/cycle, flight left/cycle, double support right/cycle, double support left/cycle, single support right/cycle, and single support left/cycle were observed between T0 and T1. All parameters improved at T1 did not show statistically significant differences a T2, with the exception of length of cycle. This small open-labeled study shows preliminary evidence that focal mechanical vibration exerted by a wearable proprioceptive stabilizer might improve limb and gait ataxia in patients affected by hereditary cerebellar ataxias.

A wearable proprioceptive stabilizer for rehabilitation of limb and gait ataxia in hereditary cerebellar ataxias. A pilot open-labeled study / Leonardi, Luca; Aceto, Maria Gabriella; Marcotulli, Christian; Arcuria, Giuseppe; Serrao, Mariano; Pierelli, Francesco; Paone, Paolo; Filla, Alessandro; Roca, Alessandro; Casali, Carlo. - In: NEUROLOGICAL SCIENCES. - ISSN 1590-1874. - 38:3(2017), pp. 459-463. [10.1007/s10072-016-2800-x]

A wearable proprioceptive stabilizer for rehabilitation of limb and gait ataxia in hereditary cerebellar ataxias. A pilot open-labeled study

LEONARDI, LUCA
;
MARCOTULLI, CHRISTIAN;SERRAO, Mariano;PIERELLI, Francesco;CASALI, Carlo
2017

Abstract

The aim of this pilot study is to test the feasibility and effectiveness of a wearable proprioceptive stabilizer that emits focal mechanical vibrations in patients affected by hereditary cerebellar ataxias. Eleven adult patients with a confirmed genetic diagnosis of autosomal dominant spinocerebellar ataxia or Friedreich's ataxia were asked to wear an active device for 3 weeks. Assessments were performed at baseline, after the device use (T1), and 3 weeks after (T2). SARA, 9-HPT, PATA, 6MWT, and spatial and temporal gait parameters, measured with a BTS-G-Walk inertial sensor, were used as study endpoints. As expected, no adverse effects were reported. Statistically significant improvements in SARA, 9HPT dominant hand, PATA test, 6MWT, cadence, length cycle, support right/cycle, support left/cycle, flight right/cycle, flight left/cycle, double support right/cycle, double support left/cycle, single support right/cycle, and single support left/cycle were observed between T0 and T1. All parameters improved at T1 did not show statistically significant differences a T2, with the exception of length of cycle. This small open-labeled study shows preliminary evidence that focal mechanical vibration exerted by a wearable proprioceptive stabilizer might improve limb and gait ataxia in patients affected by hereditary cerebellar ataxias.
2017
focal mechanical vibrations; gait ataxia; hereditary cerebellar ataxias; neurorehabilitation; female; friedreich ataxia; gait ataxia; humans; male; physical therapy modalities; pilot projects; spinocerebellar ataxias; vibration; feedback, sensory; 2708; neurology (clinical); psychiatry and mental health
01 Pubblicazione su rivista::01a Articolo in rivista
A wearable proprioceptive stabilizer for rehabilitation of limb and gait ataxia in hereditary cerebellar ataxias. A pilot open-labeled study / Leonardi, Luca; Aceto, Maria Gabriella; Marcotulli, Christian; Arcuria, Giuseppe; Serrao, Mariano; Pierelli, Francesco; Paone, Paolo; Filla, Alessandro; Roca, Alessandro; Casali, Carlo. - In: NEUROLOGICAL SCIENCES. - ISSN 1590-1874. - 38:3(2017), pp. 459-463. [10.1007/s10072-016-2800-x]
File allegati a questo prodotto
File Dimensione Formato  
Leonardi_Wearable-proprioceptive-stabilizer_2017.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 444.24 kB
Formato Adobe PDF
444.24 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/957180
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 22
social impact