Aim. To verify the tolerance of children aged between 3 and 8 years, having class I caries and treated with Er:YAG laser in association with a new self-adhesive flowable resin in comparison with a highspeed diamond bur and a conventional flowable resin treatment. Methods. A group of 80 healthy children (43 males and 37 females) ranging in age from 3 to 8 years, who had been diagnosed with at least one active occlusal non-cavitated superficial carious lesions in first or second deciduous molars, were selected for the present study. They were divided in 4 groups: group A: Class I occlusal cavities prepared using an Er: YAG laser and a self-adhesive flowable resin; Group B: Class I occlusal cavities prepared using an Er: YAG laser and a conventional flowable resin; Group C: Class I occlusal cavities prepared using a high-speed diamond bur and a self-adhesive flowable resin; Group D: Class I occlusal cavities prepared using a high-speed diamond bur and a conventional flowable resin. Before and after the treatments the patient tolerance was tested with the modified Wong-Baker pain level scale. Results. In the first group, the tolerance rate was 95% with 0 score (no hurt) for 19 patients; in Group D, the tolerance rate was 75%. Just one child of group D experienced hurting worst because of non cooperative patient. Conclusion. From these results it emerged that, although the limits of the study, Er:Yag laser in association with self-adhering composite, is very effective in pediatric dentistry and is a good treatment option especially for non cooperative patients.
Pediatric patients tolerance: a comparative study about using of Er:YAG laser and self-adhesive flowable composite for treatment of primary decayed teeth / Vozza, Iole; Mari, D; Pacifici, E; Luzzi, Valeria; Ierardo, Gaetano; Sfasciotti, Gian Luca; Polimeni, Antonella. - In: ANNALI DI STOMATOLOGIA. - ISSN 1971-1441. - 7:1-2(2016), pp. 24-28. [10.11138/ads/2016.7.1.024]
Pediatric patients tolerance: a comparative study about using of Er:YAG laser and self-adhesive flowable composite for treatment of primary decayed teeth
VOZZA, Iole
Primo
;LUZZI, Valeria;IERARDO, GAETANO;SFASCIOTTI, Gian LucaPenultimo
;POLIMENI, AntonellaUltimo
2016
Abstract
Aim. To verify the tolerance of children aged between 3 and 8 years, having class I caries and treated with Er:YAG laser in association with a new self-adhesive flowable resin in comparison with a highspeed diamond bur and a conventional flowable resin treatment. Methods. A group of 80 healthy children (43 males and 37 females) ranging in age from 3 to 8 years, who had been diagnosed with at least one active occlusal non-cavitated superficial carious lesions in first or second deciduous molars, were selected for the present study. They were divided in 4 groups: group A: Class I occlusal cavities prepared using an Er: YAG laser and a self-adhesive flowable resin; Group B: Class I occlusal cavities prepared using an Er: YAG laser and a conventional flowable resin; Group C: Class I occlusal cavities prepared using a high-speed diamond bur and a self-adhesive flowable resin; Group D: Class I occlusal cavities prepared using a high-speed diamond bur and a conventional flowable resin. Before and after the treatments the patient tolerance was tested with the modified Wong-Baker pain level scale. Results. In the first group, the tolerance rate was 95% with 0 score (no hurt) for 19 patients; in Group D, the tolerance rate was 75%. Just one child of group D experienced hurting worst because of non cooperative patient. Conclusion. From these results it emerged that, although the limits of the study, Er:Yag laser in association with self-adhering composite, is very effective in pediatric dentistry and is a good treatment option especially for non cooperative patients.File | Dimensione | Formato | |
---|---|---|---|
Vozza_Pediatric_2016.pdf
accesso aperto
Note: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6549345/
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.83 MB
Formato
Adobe PDF
|
1.83 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.