A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches with a nominal charge of 250 pC and 16 ns spacing , will collide with the laser beam in the interaction point. Electron beam spot size is measured with an OTR (optical transition radiation) profile moni-tors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accu-racy and resolution. This paper deals with the studies of different optic configurations to achieve the magnifica-tion, resolution and accuracy desired considering design and technological constraints; we will compare several configurations of the optical detection line to justify the one chosen for the implementation in the Linac

Spot size measurements in the Eli-NP compton gamma source / Cioeta, Fara; Chiadroni, E.; Cianchi, A.; Di Pirro, G.; Franzini, Giovanni; Palumbo, Luigi; Shapakov, V.; Stella, A.; Variola, A.; Marongiu, Marco; Mostacci, Andrea. - ELETTRONICO. - (2016), pp. 533-536. (Intervento presentato al convegno 5th Int. Beam Instrumentation Conf.(IBIC'16) tenutosi a Barcelona, Spain nel Sept. 13-18, 2016).

Spot size measurements in the Eli-NP compton gamma source

CIOETA, Fara;Chiadroni, E.;FRANZINI, GIOVANNI;PALUMBO, Luigi;MARONGIU, MARCO;MOSTACCI, Andrea
2016

Abstract

A high brightness electron Linac is being built in the Compton Gamma Source at the ELI Nuclear Physics facility in Romania. To achieve the design luminosity, a train of 32 bunches with a nominal charge of 250 pC and 16 ns spacing , will collide with the laser beam in the interaction point. Electron beam spot size is measured with an OTR (optical transition radiation) profile moni-tors. In order to measure the beam properties, the optical radiation detecting system must have the necessary accu-racy and resolution. This paper deals with the studies of different optic configurations to achieve the magnifica-tion, resolution and accuracy desired considering design and technological constraints; we will compare several configurations of the optical detection line to justify the one chosen for the implementation in the Linac
2016
5th Int. Beam Instrumentation Conf.(IBIC'16)
target; linac; diagnostics; optic ; radiation
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Spot size measurements in the Eli-NP compton gamma source / Cioeta, Fara; Chiadroni, E.; Cianchi, A.; Di Pirro, G.; Franzini, Giovanni; Palumbo, Luigi; Shapakov, V.; Stella, A.; Variola, A.; Marongiu, Marco; Mostacci, Andrea. - ELETTRONICO. - (2016), pp. 533-536. (Intervento presentato al convegno 5th Int. Beam Instrumentation Conf.(IBIC'16) tenutosi a Barcelona, Spain nel Sept. 13-18, 2016).
File allegati a questo prodotto
File Dimensione Formato  
tupg74.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.5 MB
Formato Adobe PDF
1.5 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/934197
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact