A Volterra model is used to calibrate a pipeline ADC simulated in Cadence Virtuoso using the STMicroelectronics CMOS 45 nm process. The ADC was designed to work at 50 MSps, but it is simulated at up to 125 MSps, proving that calibration using a Volterra model can significantly increase sampling frequency. Equivalent number of bits (ENOB) improves by 1-2.5 bits (6-15 dB) with 37101 model parameters. The complexity of the calibration algorithm is reduced using different lengths for each Volterra kernels and performing iterative pruning. System identification is performed by least squares techniques with a set of sinusoids at different frequencies spanning the whole Nyquist band. A comparison with simplified Volterra models proposed in the literature shows better performance for the pruned Volterra model with comparable complexity, improving linearity by as much as 1.5 bits more than the other techniques.

Calibration of pipeline ADC with pruned Volterra kernels / Centurelli, Francesco; Monsurro', Pietro; Rosato, Felice; Ruscio, Danilo; Trifiletti, Alessandro. - In: ELECTRONICS LETTERS. - ISSN 0013-5194. - 52:16(2016), pp. 1370-1371. [10.1049/el.2016.1601]

Calibration of pipeline ADC with pruned Volterra kernels

CENTURELLI, Francesco;MONSURRO', PIETRO;ROSATO, FELICE;RUSCIO, DANILO;TRIFILETTI, Alessandro
2016

Abstract

A Volterra model is used to calibrate a pipeline ADC simulated in Cadence Virtuoso using the STMicroelectronics CMOS 45 nm process. The ADC was designed to work at 50 MSps, but it is simulated at up to 125 MSps, proving that calibration using a Volterra model can significantly increase sampling frequency. Equivalent number of bits (ENOB) improves by 1-2.5 bits (6-15 dB) with 37101 model parameters. The complexity of the calibration algorithm is reduced using different lengths for each Volterra kernels and performing iterative pruning. System identification is performed by least squares techniques with a set of sinusoids at different frequencies spanning the whole Nyquist band. A comparison with simplified Volterra models proposed in the literature shows better performance for the pruned Volterra model with comparable complexity, improving linearity by as much as 1.5 bits more than the other techniques.
2016
Calibration; iterative methods; pipelines
01 Pubblicazione su rivista::01a Articolo in rivista
Calibration of pipeline ADC with pruned Volterra kernels / Centurelli, Francesco; Monsurro', Pietro; Rosato, Felice; Ruscio, Danilo; Trifiletti, Alessandro. - In: ELECTRONICS LETTERS. - ISSN 0013-5194. - 52:16(2016), pp. 1370-1371. [10.1049/el.2016.1601]
File allegati a questo prodotto
File Dimensione Formato  
Centurelli_Calibration_2016.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 159.67 kB
Formato Adobe PDF
159.67 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/911791
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 2
social impact