Purpose. Various parameters can influence temperature rise and detection during implant site preparation. The aim of this study is to investigate local temperature values in cortical and corticocancellous bovine bone during early stages of piezoelectric implant site preparation. Materials and Methods. 20 osteotomies were performed using a diamond tip (IM1s, Mectron Medical Technology, Carasco, Italy) on two different types of bovine bone samples, cortical and corticocancellous, respectively. A standardized protocol was designed to provide constant working conditions. Temperatures were measured in real time at a fixed position by a fiber optic thermometer. Results. Significantly higher drilling time (154.90 sec versus 99.00 sec; p < 0.0001) and temperatures (39.26°C versus 34.73°C; p = 0.043) were observed in the cortical group compared to the corticocancellous group. A remarkable variability of results characterized the corticocancellous blocks as compared to the blocks of pure cortical bone. Conclusion. Bone samples can influence heat generation during in vitro implant site preparation. When compared to cortical bone, corticocancellous samples present more variability in temperature values. Even controlling most experimental factors, the impact of bone samples still remains one of the main causes of temperature variability.

Temperature values variability in piezoelectric implant site preparation: differences between cortical and corticocancellous bovine bone / Lamazza, Luca; Garreffa, Girolamo; Laurito, Domenica; Lollobrigida, Marco; Palmieri, Luigi; DE BIASE, Alberto. - In: BIOMED RESEARCH INTERNATIONAL. - ISSN 2314-6141. - ELETTRONICO. - 2016:(2016), pp. 1-7. [10.1155/2016/6473680]

Temperature values variability in piezoelectric implant site preparation: differences between cortical and corticocancellous bovine bone

LAMAZZA, LUCA
Primo
;
Garreffa, Girolamo
Secondo
;
LAURITO, DOMENICA;Lollobrigida, Marco
;
DE BIASE, Alberto
Ultimo
2016

Abstract

Purpose. Various parameters can influence temperature rise and detection during implant site preparation. The aim of this study is to investigate local temperature values in cortical and corticocancellous bovine bone during early stages of piezoelectric implant site preparation. Materials and Methods. 20 osteotomies were performed using a diamond tip (IM1s, Mectron Medical Technology, Carasco, Italy) on two different types of bovine bone samples, cortical and corticocancellous, respectively. A standardized protocol was designed to provide constant working conditions. Temperatures were measured in real time at a fixed position by a fiber optic thermometer. Results. Significantly higher drilling time (154.90 sec versus 99.00 sec; p < 0.0001) and temperatures (39.26°C versus 34.73°C; p = 0.043) were observed in the cortical group compared to the corticocancellous group. A remarkable variability of results characterized the corticocancellous blocks as compared to the blocks of pure cortical bone. Conclusion. Bone samples can influence heat generation during in vitro implant site preparation. When compared to cortical bone, corticocancellous samples present more variability in temperature values. Even controlling most experimental factors, the impact of bone samples still remains one of the main causes of temperature variability.
2016
dental implants; osteotomies; in-vitro; corticocancellous bone; piezoelectricity; temperature
01 Pubblicazione su rivista::01a Articolo in rivista
Temperature values variability in piezoelectric implant site preparation: differences between cortical and corticocancellous bovine bone / Lamazza, Luca; Garreffa, Girolamo; Laurito, Domenica; Lollobrigida, Marco; Palmieri, Luigi; DE BIASE, Alberto. - In: BIOMED RESEARCH INTERNATIONAL. - ISSN 2314-6141. - ELETTRONICO. - 2016:(2016), pp. 1-7. [10.1155/2016/6473680]
File allegati a questo prodotto
File Dimensione Formato  
Lamazza_Temperature_2016.pdf

accesso aperto

Note: https://www.hindawi.com/journals/bmri/2016/6473680/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.85 MB
Formato Adobe PDF
3.85 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/851681
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact