Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
The Virgo experiment, located near Pisa, Italy, is a large laser Michelson interferometer aiming at the first direct detection of gravitational waves. The interferometer monitors the relative distance of its mirrors placed at the ends of two 3 km-long perpendicular arms. The goal is to measure spectral differential variations of the arm lengths of 10 <-18< m/Hz< in the frequency range from 10 Hz to 10 kHz. Avoiding spurious motions of the optical components is therefore essential to detect gravitational waves. Since the ground motion is 9 orders of magnitude larger than the arm length variations induced by gravitational waves, the seismic noise is the dominant low frequency noise source for terrestrial gravitational wave interferometers. The seismic isolation is obtained suspending the mirrors by an 8-meter tall chain of cascaded mechanical filters, called "Superattenuator" (SA). The Superattenuator is a passive device acting as a low pass filter in all six degrees of freedom, capable of attenuating the ground motion by more than 10 orders of magnitude, starting from a few Hz. To further reduce the seismic disturbances, the filter chain is suspended from an actively stabilized platform that compensates for low frequency and large amplitude oscillations caused by the mechanical resonances of the chain. In this article we describe the Superattenuator together with its control system, and we report about its performance.
The seismic Superattenuators of the Virgo gravitational waves interferometer / Accadia, T.; Acernese, F.; Antonucci, F.; Astone, P.; Ballardin, G.; Barone, F.; Barsuglia, M.; Bauer, Th. S.; Beker, M. G.; Belletoile, A.; Birindelli, S.; Bitossi, M.; Bizouard, M. A.; Blom, M.; Boccara, C.; Bondu, F.; Bonelli, L.; Bonnand, R.; Boschi, V.; Bosi, L.; Bouhou, B.; Braccini, S.; Bradaschia, C.; Brillet, A.; Brisson, V.; Budzynski, R.; Bulik, T.; Bulten, H. J.; Buskulic, D.; Buy, C.; Cagnoli, G.; Calloni, E.; Campagna, E.; Canuel, B.; Carbognani, F.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cesarini, E.; Chassande-Mottin, E.; Chincarini, A.; Cleva, F.; Coccia, E.; Colacino, C. N.; Colas, J.; Colla, A.; Colombini, M.; Corsi, A.; Coulon, J. -P.; Cuoco, E.; D'Antonio, S.; Dattilo, V.; Davier, M.; Day, R.; De Rosa, R.; Debreczeni, G.; del Prete, M.; Di Fiore, L.; Di Lieto, A.; Di Paolo Emilio, M.; Di Virgilio, A.; Dietz, A.; Drago, M.; Fafone, V.; Ferrante, I.; Fidecaro, F.; Fiori, I.; Flaminio, R.; Fournier, J. -D.; Franc, J.; Frasca, S.; Frasconi, F.; Freise, A.; Galimberti, M.; Gammaitoni, L.; Garufi, F.; Gáspár, M. E.; Gemme, G.; Genin, E.; Gennai, A.; Giazotto, A.; Gouaty, R.; Granata, M.; Greverie, C.; Guidi, G. M.; Hayau, J. -F.; Heitmann, H.; Hello, P.; Hild, S.; Huet, D.; Jaranowski, P.; Kowalska, I.; Królak, A.; Leroy, N.; Letendre, N.; Li, T. G. F.; Lorenzini, M.; Loriette, V.; Losurdo, G.; Majorana, E.; Maksimovic, I.; Man, N.; Mantovani, M.; Marchesoni, F.; Marion, F.; Marque, J.; Martelli, F.; Masserot, A.; Michel, C.; Milano, L.; Minenkov, Y.; Mohan, M.; Moreau, J.; Morgado, N.; Morgia, A.; Mosca, S.; Moscatelli, V.; Mours, B.; Neri, I.; Nocera, F.; Pagliaroli, G.; Palladino, L.; Palomba, C.; It, F. Paoletti federico. paoletti@pi. infn.; Pardi, S.; Parisi, M.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Persichetti, G.; Pichot, M.; Piergiovanni, F.; Pietka, M.; Pinard, L.; Poggiani, R.; Prato, M.; Prodi, G. A.; Punturo, M.; Puppo, P.; Rabeling, D. S.; Rácz, I.; Rapagnani, P.; Re, V.; Regimbau, T.; Ricci, F.; Robinet, F.; Rocchi, A.; Rolland, L.; Romano, R.; Rosinska, D.; Ruggi, P.; Sassolas, B.; Sentenac, D.; Sperandio, L.; Sturani, R.; Swinkels, B.; Toncelli, A.; Tonelli, M.; Torre, O.; Tournefier, E.; Travasso, F.; Vajente, G.; van den Brand, J. F. J.; van der Putten, S.; Vasuth, M.; Vavoulidis, M.; Vedovato, G.; Verkindt, D.; Vetrano, F.; Viceré, A; Vinet, J. -Y.; Vocca, H.; Was, M.; Yvert, M.. - In: JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL. - ISSN 1461-3484. - STAMPA. - 30:1(2011), pp. 63-79. [10.1260/0263-0923.30.1.63]
The seismic Superattenuators of the Virgo gravitational waves interferometer
T. Accadia;F. Acernese;F. Antonucci;P. Astone;G. Ballardin;F. Barone;M. Barsuglia;Th. S. Bauer;M. G. Beker;A. Belletoile;S. Birindelli;M. Bitossi;M. A. Bizouard;M. Blom;C. Boccara;F. Bondu;L. Bonelli;R. Bonnand;V. Boschi;L. Bosi;B. Bouhou;S. Braccini;C. Bradaschia;A. Brillet;V. Brisson;R. Budzynski;T. Bulik;H. J. Bulten;D. Buskulic;C. Buy;G. Cagnoli;E. Calloni;E. Campagna;B. Canuel;F. Carbognani;F. Cavalier;R. Cavalieri;G. Cella;E. Cesarini;E. Chassande-Mottin;A. Chincarini;F. Cleva;E. Coccia;C. N. Colacino;J. Colas;A. Colla;M. Colombini;A. Corsi;J. -P. Coulon;E. Cuoco;S. D'Antonio;V. Dattilo;M. Davier;R. Day;R. De Rosa;G. Debreczeni;M. del Prete;L. Di Fiore;A. Di Lieto;M. Di Paolo Emilio;A. Di Virgilio;A. Dietz;M. Drago;V. Fafone;I. Ferrante;F. Fidecaro;I. Fiori;R. Flaminio;J. -D. Fournier;J. Franc;S. Frasca;F. Frasconi;A. Freise;M. Galimberti;L. Gammaitoni;F. Garufi;M. E. Gáspár;G. Gemme;E. Genin;A. Gennai;A. Giazotto;R. Gouaty;M. Granata;C. Greverie;G. M. Guidi;J. -F. Hayau;H. Heitmann;P. Hello;S. Hild;D. Huet;P. Jaranowski;I. Kowalska;A. Królak;N. Leroy;N. Letendre;T. G. F. Li;M. Lorenzini;V. Loriette;G. Losurdo;E. Majorana;I. Maksimovic;N. Man;M. Mantovani;F. Marchesoni;F. Marion;J. Marque;F. Martelli;A. Masserot;C. Michel;L. Milano;Y. Minenkov;M. Mohan;J. Moreau;N. Morgado;A. Morgia;S. Mosca;V. Moscatelli;B. Mours;I. Neri;F. Nocera;G. Pagliaroli;L. Palladino;C. Palomba;F. Paoletti federico. paoletti@pi. infn. it;S. Pardi;M. Parisi;A. Pasqualetti;R. Passaquieti;D. Passuello;G. Persichetti;M. Pichot;F. Piergiovanni;M. Pietka;L. Pinard;R. Poggiani;M. Prato;G. A. Prodi;M. Punturo;P. Puppo;D. S. Rabeling;I. Rácz;P. Rapagnani;V. Re;T. Regimbau;F. Ricci;F. Robinet;A. Rocchi;L. Rolland;R. Romano;D. Rosinska;P. Ruggi;B. Sassolas;D. Sentenac;L. Sperandio;R. Sturani;B. Swinkels;A. Toncelli;M. Tonelli;O. Torre;E. Tournefier;F. Travasso;G. Vajente;J. F. J. van den Brand;S. van der Putten;M. Vasuth;M. Vavoulidis;G. Vedovato;D. Verkindt;F. Vetrano;A Viceré;J. -Y. Vinet;H. Vocca;M. Was;M. Yvert
2011
Abstract
The Virgo experiment, located near Pisa, Italy, is a large laser Michelson interferometer aiming at the first direct detection of gravitational waves. The interferometer monitors the relative distance of its mirrors placed at the ends of two 3 km-long perpendicular arms. The goal is to measure spectral differential variations of the arm lengths of 10 <-18< m/Hz< in the frequency range from 10 Hz to 10 kHz. Avoiding spurious motions of the optical components is therefore essential to detect gravitational waves. Since the ground motion is 9 orders of magnitude larger than the arm length variations induced by gravitational waves, the seismic noise is the dominant low frequency noise source for terrestrial gravitational wave interferometers. The seismic isolation is obtained suspending the mirrors by an 8-meter tall chain of cascaded mechanical filters, called "Superattenuator" (SA). The Superattenuator is a passive device acting as a low pass filter in all six degrees of freedom, capable of attenuating the ground motion by more than 10 orders of magnitude, starting from a few Hz. To further reduce the seismic disturbances, the filter chain is suspended from an actively stabilized platform that compensates for low frequency and large amplitude oscillations caused by the mechanical resonances of the chain. In this article we describe the Superattenuator together with its control system, and we report about its performance.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/503996
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
35
26
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.