Background: The accuracy of a stereolithographic surgical guide depends on several variables that can affect at any time from the software-planning stage to the surgical field. AIM: The purpose of this study was to evaluate the accuracy of implants inserted using a single mucosa-supported stereolithographic surgical guide determining also the influence of surgical technique (fixed and not-fixed) and smoking on the deviation parameters. MATERIALS AND METHODS: 11 patients, totally edentate in the upper arch and needed an implant-prosthetic rehabilitation, were selected. 95 implants were planned and inserted. The preand post-operative CT images were compared using software. RESULTS: Global, coronal (Mean: 1.65; Range: 3.00-0.13; SD:0.56) and apical (Mean: 2.15; Range: 4.23-0.34; SD:0.81), and angular (Mean: 4.62; Range: 15.25-0.28; SD: 2.74) deviation values were determined. The mean values of mucosa thickness in smokers and nonsmokers patients were 4.53 mm and 3.42 mm respectively (p < .05). The accuracy data showed a better result for the angular deviation when the surgical template was fixed (p = .002) and a better global apical deviation in the nonsmokers (p <. 05). CONCLUSiOiSiS: It is essential, especially in smoker patients, to respect a minimum safety distance of 3 mm from limiting anatomic structures.

The influence of smoking and surgical technique on the accuracy of mucosa-suppoted stereolithographic surgical guide in complete edentulous upper jaws / Cassetta, Michele; Pompa, Giorgio; DI CARLO, Stefano; Piccoli, Luca; Pacifici, Andrea; Pacifici, Luciano. - In: EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES. - ISSN 1128-3602. - STAMPA. - 16:11(2012), pp. 1546-1553.

The influence of smoking and surgical technique on the accuracy of mucosa-suppoted stereolithographic surgical guide in complete edentulous upper jaws

CASSETTA, Michele;POMPA, Giorgio;DI CARLO, Stefano;PICCOLI, Luca;PACIFICI, ANDREA;PACIFICI, Luciano
2012

Abstract

Background: The accuracy of a stereolithographic surgical guide depends on several variables that can affect at any time from the software-planning stage to the surgical field. AIM: The purpose of this study was to evaluate the accuracy of implants inserted using a single mucosa-supported stereolithographic surgical guide determining also the influence of surgical technique (fixed and not-fixed) and smoking on the deviation parameters. MATERIALS AND METHODS: 11 patients, totally edentate in the upper arch and needed an implant-prosthetic rehabilitation, were selected. 95 implants were planned and inserted. The preand post-operative CT images were compared using software. RESULTS: Global, coronal (Mean: 1.65; Range: 3.00-0.13; SD:0.56) and apical (Mean: 2.15; Range: 4.23-0.34; SD:0.81), and angular (Mean: 4.62; Range: 15.25-0.28; SD: 2.74) deviation values were determined. The mean values of mucosa thickness in smokers and nonsmokers patients were 4.53 mm and 3.42 mm respectively (p < .05). The accuracy data showed a better result for the angular deviation when the surgical template was fixed (p = .002) and a better global apical deviation in the nonsmokers (p <. 05). CONCLUSiOiSiS: It is essential, especially in smoker patients, to respect a minimum safety distance of 3 mm from limiting anatomic structures.
2012
guide; template; surgical; edentulous; implants; accuracy; stereolithographic
01 Pubblicazione su rivista::01a Articolo in rivista
The influence of smoking and surgical technique on the accuracy of mucosa-suppoted stereolithographic surgical guide in complete edentulous upper jaws / Cassetta, Michele; Pompa, Giorgio; DI CARLO, Stefano; Piccoli, Luca; Pacifici, Andrea; Pacifici, Luciano. - In: EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES. - ISSN 1128-3602. - STAMPA. - 16:11(2012), pp. 1546-1553.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/496915
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 18
social impact