An automatic and sensitive HPLC method for the determination of primary and secondary amino acids included cystine and homocystine in urine samples is described. After a simple ultrafiltration, urine samples were subjected to reduction of disulfides, carboxymethylation of free thiols and double precolumn derivatization with o-phthalaldehyde-3-mercaptopropionic acid and 9-fluroenylmethyl chloroformate. All reactions were fully automated by means of an injector programme and were accomplished in 10 min. Since urine samples contain a large number of amino compounds, a good resolution was required. By optimization of the conditions, separation of 40 amino acids in 92 min was achieved. The recovery of amino acids ranged from 83% for TRP to 105% for CIT. The within-run and between-run R.S.D.s of urinary amino acid concentrations were below 10% for most amino acids except for HYL, LYS and ORN. The method was applied to the diagnosis of genetic disorders of amino acid metabolism.

Automated method for the measurement of amino acids in urine by high-performance liquid chromatography / Carducci, Claudia; Birarelli, Maurizio; Leuzzi, Vincenzo; Santagata, Giuseppe; Serafini, P; Antonozzi, Italo. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 729:(1996), pp. 173-180.

Automated method for the measurement of amino acids in urine by high-performance liquid chromatography.

CARDUCCI, Claudia;BIRARELLI, Maurizio;LEUZZI, Vincenzo;SANTAGATA, Giuseppe;ANTONOZZI, Italo
1996

Abstract

An automatic and sensitive HPLC method for the determination of primary and secondary amino acids included cystine and homocystine in urine samples is described. After a simple ultrafiltration, urine samples were subjected to reduction of disulfides, carboxymethylation of free thiols and double precolumn derivatization with o-phthalaldehyde-3-mercaptopropionic acid and 9-fluroenylmethyl chloroformate. All reactions were fully automated by means of an injector programme and were accomplished in 10 min. Since urine samples contain a large number of amino compounds, a good resolution was required. By optimization of the conditions, separation of 40 amino acids in 92 min was achieved. The recovery of amino acids ranged from 83% for TRP to 105% for CIT. The within-run and between-run R.S.D.s of urinary amino acid concentrations were below 10% for most amino acids except for HYL, LYS and ORN. The method was applied to the diagnosis of genetic disorders of amino acid metabolism.
1996
01 Pubblicazione su rivista::01a Articolo in rivista
Automated method for the measurement of amino acids in urine by high-performance liquid chromatography / Carducci, Claudia; Birarelli, Maurizio; Leuzzi, Vincenzo; Santagata, Giuseppe; Serafini, P; Antonozzi, Italo. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 729:(1996), pp. 173-180.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/491216
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 34
social impact