We compared unenhanced and contrast-enhanced fast MRI and CT in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to CT and MR studies; T1- and T2-weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T super-conductive magnet (Philips NT). The quantitative analysis of all MR images was performed for contrast/noise ratio (CNR) and number of detected lesions; MR and CT images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's t test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and CT (p = .0004) for lesion conspicuity and to T1-weighted TSE, T2-weighted TSE, unenhanced TFE (p = .0001) and CT (p = .01) for anatomical structure identification. CT was superior to T1- and T2-weighted TSE (p = .0001) and unenhanced TFE (p = .004) for the lack of artifacts. Fat-suppressed T2-weighted TSE images had a statistically higher CNR than T2-weighted TSE (p = .02), T1-weighted TSE (p = .0006) and unenhanced and delayed TFE sequences (p = .007; p = .0001, respectively). To conclude, MRI appears superior to CT in the detection of liver metastases; the examination should include early enhanced breath-hold T1-weighted TFE and T2-weighted fat-suppressed TSE images.

[Comparison of computerized tomography and magnetic resonance with fast sequences with and without paramagnetic contrast media in the assessment of liver metastasis: qualitative and quantitative analysis] / Maccioni, Francesca; L., Broglia; Rossi, Plinio. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 93:6(1997), pp. 708-714.

[Comparison of computerized tomography and magnetic resonance with fast sequences with and without paramagnetic contrast media in the assessment of liver metastasis: qualitative and quantitative analysis].

MACCIONI, Francesca;ROSSI, Plinio
1997

Abstract

We compared unenhanced and contrast-enhanced fast MRI and CT in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to CT and MR studies; T1- and T2-weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T super-conductive magnet (Philips NT). The quantitative analysis of all MR images was performed for contrast/noise ratio (CNR) and number of detected lesions; MR and CT images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's t test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and CT (p = .0004) for lesion conspicuity and to T1-weighted TSE, T2-weighted TSE, unenhanced TFE (p = .0001) and CT (p = .01) for anatomical structure identification. CT was superior to T1- and T2-weighted TSE (p = .0001) and unenhanced TFE (p = .004) for the lack of artifacts. Fat-suppressed T2-weighted TSE images had a statistically higher CNR than T2-weighted TSE (p = .02), T1-weighted TSE (p = .0006) and unenhanced and delayed TFE sequences (p = .007; p = .0001, respectively). To conclude, MRI appears superior to CT in the detection of liver metastases; the examination should include early enhanced breath-hold T1-weighted TFE and T2-weighted fat-suppressed TSE images.
1997
01 Pubblicazione su rivista::01a Articolo in rivista
[Comparison of computerized tomography and magnetic resonance with fast sequences with and without paramagnetic contrast media in the assessment of liver metastasis: qualitative and quantitative analysis] / Maccioni, Francesca; L., Broglia; Rossi, Plinio. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - 93:6(1997), pp. 708-714.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/489088
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact