The aim of the present study was to assess the clinical relevance of the potential mechanical error (intrinsic error) caused by the cylinder-burr gap in a 'single type' stereolithographic surgical template in implant guided surgery. 129 implants were inserted in 12 patients using 18 templates. The pre- and postoperative computed tomography (CT) scans were matched allowing comparison of the planned implants with the placed ones. Considering only the angular deviation values, the t test was used to determine the influence of the guide fixation and the arch of support on accuracy values. The Pearson correlation coefficient was used to correlate angular deviation and bone density. The intrinsic error was mathematically evaluated. t test results indicated that the use of fixing screws (P = 009) and the upper arch support (P = 027) resulted in better accuracy. The Pearson correlation coefficient (0.229) indicated a significant linear correlation between angular deviations and bone density (P = 009). A mean intrinsic error of 2.57 was mathematically determined considering only the angular deviation, as it was not influenced by other variables. The intrinsic error is a significant factor compared to all the variables that could potentially affect the accuracy of computer-aided implant placement. © 2012 International Association of Oral and Maxillofacial Surgeons.

The intrinsic error of a stereolithographic surgical template in implant guided surgery / Cassetta, Michele; A., Di Mambro; Giansanti, Matteo; L. v., Stefanelli; Cavallini, Costanza. - In: INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0901-5027. - ELETTRONICO. - 42:2(2013), pp. 264-275. [10.1016/j.ijom.2012.06.010]

The intrinsic error of a stereolithographic surgical template in implant guided surgery

CASSETTA, Michele;GIANSANTI, MATTEO;CAVALLINI, COSTANZA
2013

Abstract

The aim of the present study was to assess the clinical relevance of the potential mechanical error (intrinsic error) caused by the cylinder-burr gap in a 'single type' stereolithographic surgical template in implant guided surgery. 129 implants were inserted in 12 patients using 18 templates. The pre- and postoperative computed tomography (CT) scans were matched allowing comparison of the planned implants with the placed ones. Considering only the angular deviation values, the t test was used to determine the influence of the guide fixation and the arch of support on accuracy values. The Pearson correlation coefficient was used to correlate angular deviation and bone density. The intrinsic error was mathematically evaluated. t test results indicated that the use of fixing screws (P = 009) and the upper arch support (P = 027) resulted in better accuracy. The Pearson correlation coefficient (0.229) indicated a significant linear correlation between angular deviations and bone density (P = 009). A mean intrinsic error of 2.57 was mathematically determined considering only the angular deviation, as it was not influenced by other variables. The intrinsic error is a significant factor compared to all the variables that could potentially affect the accuracy of computer-aided implant placement. © 2012 International Association of Oral and Maxillofacial Surgeons.
2013
intrinsic error; stereolithographic surgical guide; computer-aided implantology; surgical template; accuracy
01 Pubblicazione su rivista::01a Articolo in rivista
The intrinsic error of a stereolithographic surgical template in implant guided surgery / Cassetta, Michele; A., Di Mambro; Giansanti, Matteo; L. v., Stefanelli; Cavallini, Costanza. - In: INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0901-5027. - ELETTRONICO. - 42:2(2013), pp. 264-275. [10.1016/j.ijom.2012.06.010]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/483953
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 31
  • Scopus 110
  • ???jsp.display-item.citation.isi??? 103
social impact