The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, 6 months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data and the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency domain is described and typical sensitivities measured during VSR2 are shown.

Calibration and sensitivity of the Virgo detector during its second science run / T., Accadia; F., Acernese; F., Antonucci; P., Astone; G., Ballardin; F., Barone; M., Barsuglia; A., Basti; Th S., Bauer; M. G., Beker; A., Belletoile; S., Birindelli; M., Bitossi; M. A., Bizouard; M., Blom; F., Bondu; L., Bonelli; R., Bonnand; V., Boschi; L., Bosi; B., Bouhou; S., Braccini; C., Bradaschia; A., Brillet; V., Brisson; R., Budzynski; T., Bulik; H. J., Bulten; D., Buskulic; C., Buy; G., Cagnoli; E., Calloni; E., Campagna; B., Canuel; F., Carbognani; F., Cavalier; R., Cavalieri; G., Cella; E., Cesarini; O., Chaibi; E. C., Mottin; A., Chincarini; F., Cleva; E., Coccia; C. N., Colacino; J., Colas; Colla, Alberto; M., Colombini; A., Corsi; J. P., Coulon; E., Cuoco; S., D'Antonio; V., Dattilo; M., Davier; R., Day; R., De Rosa; G., Debreczeni; M., Del Prete; L., Di Fiore; A., Di Lieto; Emilio, Md; A., Di Virgilio; A., Dietz; M., Drago; V., Fafone; I., Ferrante; F., Fidecaro; I., Fiori; R., Flaminio; L. A., Forte; J. D., Fournier; J., Franc; Frasca, Sergio; F., Frasconi; A., Freise; M., Galimberti; L., Gammaitoni; F., Garufi; M. E., Gaspar; G., Gemme; E., Genin; A., Gennai; A., Giazotto; R., Gouaty; M., Granata; C., Greverie; G. M., Guidi; J. F., Hayau; H., Heitmann; P., Hello; S., Hild; D., Huet; P., Jaranowskie; I., Kowalska; A., Krolak; N., Leroy; N., Letendre; L. I., Tgf; N., Liguori; M., Lorenzini; V., Loriette; G., Losurdo; E., Majorana; I., Maksimovic; N., Man; M., Mantovani; F., Marchesoni; F., Marion; J., Marque; F., Martelli; A., Masserot; C., Michel; L., Milano; Y., Minenkov; M., Mohan; N., Morgado; A., Morgia; S., Mosca; V., Moscatelli; B., Mours; F., Nocera; G., Pagliaroli; L., Palladino; C., Palomba; F., Paoletti; S., Pardi; M., Parisi; A., Pasqualetti; R., Passaquieti; D., Passuello; G., Persichetti; M., Pichot; F., Piergiovanni; M., Pietka; L., Pinard; R., Poggiani; M., Prato; G. A., Prodi; M., Punturo; P., Puppo; D. S., Rabeling; I., Racz; Rapagnani, Piero; V., Re; T., Regimbau; Ricci, Fulvio; F., Robinet; A., Rocchi; L., Rolland; R., Romano; D., Rosinska; P., Ruggi; B., Sassolas; D., Sentenac; L., Sperandio; R., Sturani; B., Swinkels; M., Tacca; A., Toncelli; M., Tonelli; O., Torre; E., Tournefier; F., Travasso; G., Vajente; J. F. J., Van Den Brand; S., Van Der Putten; M., Vasuth; M., Vavoulidis; G., Vedovato; D., Verkindt; F., Vetrano; A., Vicere; J. Y., Vinet; H., Vocca; R. L., Ward; M., Was; M., Yvert. - In: CLASSICAL AND QUANTUM GRAVITY. - ISSN 0264-9381. - 28:2(2011), p. 025005. [10.1088/0264-9381/28/2/025005]

Calibration and sensitivity of the Virgo detector during its second science run

COLLA, ALBERTO;M. Drago;FRASCA, Sergio;E. Majorana;RAPAGNANI, Piero;RICCI, Fulvio;
2011

Abstract

The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, 6 months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data and the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency domain is described and typical sensitivities measured during VSR2 are shown.
2011
01 Pubblicazione su rivista::01a Articolo in rivista
Calibration and sensitivity of the Virgo detector during its second science run / T., Accadia; F., Acernese; F., Antonucci; P., Astone; G., Ballardin; F., Barone; M., Barsuglia; A., Basti; Th S., Bauer; M. G., Beker; A., Belletoile; S., Birindelli; M., Bitossi; M. A., Bizouard; M., Blom; F., Bondu; L., Bonelli; R., Bonnand; V., Boschi; L., Bosi; B., Bouhou; S., Braccini; C., Bradaschia; A., Brillet; V., Brisson; R., Budzynski; T., Bulik; H. J., Bulten; D., Buskulic; C., Buy; G., Cagnoli; E., Calloni; E., Campagna; B., Canuel; F., Carbognani; F., Cavalier; R., Cavalieri; G., Cella; E., Cesarini; O., Chaibi; E. C., Mottin; A., Chincarini; F., Cleva; E., Coccia; C. N., Colacino; J., Colas; Colla, Alberto; M., Colombini; A., Corsi; J. P., Coulon; E., Cuoco; S., D'Antonio; V., Dattilo; M., Davier; R., Day; R., De Rosa; G., Debreczeni; M., Del Prete; L., Di Fiore; A., Di Lieto; Emilio, Md; A., Di Virgilio; A., Dietz; M., Drago; V., Fafone; I., Ferrante; F., Fidecaro; I., Fiori; R., Flaminio; L. A., Forte; J. D., Fournier; J., Franc; Frasca, Sergio; F., Frasconi; A., Freise; M., Galimberti; L., Gammaitoni; F., Garufi; M. E., Gaspar; G., Gemme; E., Genin; A., Gennai; A., Giazotto; R., Gouaty; M., Granata; C., Greverie; G. M., Guidi; J. F., Hayau; H., Heitmann; P., Hello; S., Hild; D., Huet; P., Jaranowskie; I., Kowalska; A., Krolak; N., Leroy; N., Letendre; L. I., Tgf; N., Liguori; M., Lorenzini; V., Loriette; G., Losurdo; E., Majorana; I., Maksimovic; N., Man; M., Mantovani; F., Marchesoni; F., Marion; J., Marque; F., Martelli; A., Masserot; C., Michel; L., Milano; Y., Minenkov; M., Mohan; N., Morgado; A., Morgia; S., Mosca; V., Moscatelli; B., Mours; F., Nocera; G., Pagliaroli; L., Palladino; C., Palomba; F., Paoletti; S., Pardi; M., Parisi; A., Pasqualetti; R., Passaquieti; D., Passuello; G., Persichetti; M., Pichot; F., Piergiovanni; M., Pietka; L., Pinard; R., Poggiani; M., Prato; G. A., Prodi; M., Punturo; P., Puppo; D. S., Rabeling; I., Racz; Rapagnani, Piero; V., Re; T., Regimbau; Ricci, Fulvio; F., Robinet; A., Rocchi; L., Rolland; R., Romano; D., Rosinska; P., Ruggi; B., Sassolas; D., Sentenac; L., Sperandio; R., Sturani; B., Swinkels; M., Tacca; A., Toncelli; M., Tonelli; O., Torre; E., Tournefier; F., Travasso; G., Vajente; J. F. J., Van Den Brand; S., Van Der Putten; M., Vasuth; M., Vavoulidis; G., Vedovato; D., Verkindt; F., Vetrano; A., Vicere; J. Y., Vinet; H., Vocca; R. L., Ward; M., Was; M., Yvert. - In: CLASSICAL AND QUANTUM GRAVITY. - ISSN 0264-9381. - 28:2(2011), p. 025005. [10.1088/0264-9381/28/2/025005]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/378579
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 74
  • ???jsp.display-item.citation.isi??? 67
social impact