Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, 6 months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data and the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency domain is described and typical sensitivities measured during VSR2 are shown.
Calibration and sensitivity of the Virgo detector during its second science run / T., Accadia; F., Acernese; F., Antonucci; P., Astone; G., Ballardin; F., Barone; M., Barsuglia; A., Basti; Th S., Bauer; M. G., Beker; A., Belletoile; S., Birindelli; M., Bitossi; M. A., Bizouard; M., Blom; F., Bondu; L., Bonelli; R., Bonnand; V., Boschi; L., Bosi; B., Bouhou; S., Braccini; C., Bradaschia; A., Brillet; V., Brisson; R., Budzynski; T., Bulik; H. J., Bulten; D., Buskulic; C., Buy; G., Cagnoli; E., Calloni; E., Campagna; B., Canuel; F., Carbognani; F., Cavalier; R., Cavalieri; G., Cella; E., Cesarini; O., Chaibi; E. C., Mottin; A., Chincarini; F., Cleva; E., Coccia; C. N., Colacino; J., Colas; Colla, Alberto; M., Colombini; A., Corsi; J. P., Coulon; E., Cuoco; S., D'Antonio; V., Dattilo; M., Davier; R., Day; R., De Rosa; G., Debreczeni; M., Del Prete; L., Di Fiore; A., Di Lieto; Emilio, Md; A., Di Virgilio; A., Dietz; M., Drago; V., Fafone; I., Ferrante; F., Fidecaro; I., Fiori; R., Flaminio; L. A., Forte; J. D., Fournier; J., Franc; Frasca, Sergio; F., Frasconi; A., Freise; M., Galimberti; L., Gammaitoni; F., Garufi; M. E., Gaspar; G., Gemme; E., Genin; A., Gennai; A., Giazotto; R., Gouaty; M., Granata; C., Greverie; G. M., Guidi; J. F., Hayau; H., Heitmann; P., Hello; S., Hild; D., Huet; P., Jaranowskie; I., Kowalska; A., Krolak; N., Leroy; N., Letendre; L. I., Tgf; N., Liguori; M., Lorenzini; V., Loriette; G., Losurdo; E., Majorana; I., Maksimovic; N., Man; M., Mantovani; F., Marchesoni; F., Marion; J., Marque; F., Martelli; A., Masserot; C., Michel; L., Milano; Y., Minenkov; M., Mohan; N., Morgado; A., Morgia; S., Mosca; V., Moscatelli; B., Mours; F., Nocera; G., Pagliaroli; L., Palladino; C., Palomba; F., Paoletti; S., Pardi; M., Parisi; A., Pasqualetti; R., Passaquieti; D., Passuello; G., Persichetti; M., Pichot; F., Piergiovanni; M., Pietka; L., Pinard; R., Poggiani; M., Prato; G. A., Prodi; M., Punturo; P., Puppo; D. S., Rabeling; I., Racz; Rapagnani, Piero; V., Re; T., Regimbau; Ricci, Fulvio; F., Robinet; A., Rocchi; L., Rolland; R., Romano; D., Rosinska; P., Ruggi; B., Sassolas; D., Sentenac; L., Sperandio; R., Sturani; B., Swinkels; M., Tacca; A., Toncelli; M., Tonelli; O., Torre; E., Tournefier; F., Travasso; G., Vajente; J. F. J., Van Den Brand; S., Van Der Putten; M., Vasuth; M., Vavoulidis; G., Vedovato; D., Verkindt; F., Vetrano; A., Vicere; J. Y., Vinet; H., Vocca; R. L., Ward; M., Was; M., Yvert. - In: CLASSICAL AND QUANTUM GRAVITY. - ISSN 0264-9381. - 28:2(2011), p. 025005. [10.1088/0264-9381/28/2/025005]
Calibration and sensitivity of the Virgo detector during its second science run
T. Accadia;F. Acernese;F. Antonucci;P. Astone;G. Ballardin;F. Barone;M. Barsuglia;A. Basti;Th S. Bauer;M. G. Beker;A. Belletoile;S. Birindelli;M. Bitossi;M. A. Bizouard;M. Blom;F. Bondu;L. Bonelli;R. Bonnand;V. Boschi;L. Bosi;B. Bouhou;S. Braccini;C. Bradaschia;A. Brillet;V. Brisson;R. Budzynski;T. Bulik;H. J. Bulten;D. Buskulic;C. Buy;G. Cagnoli;E. Calloni;E. Campagna;B. Canuel;F. Carbognani;F. Cavalier;R. Cavalieri;G. Cella;E. Cesarini;O. Chaibi;E. C. Mottin;A. Chincarini;F. Cleva;E. Coccia;C. N. Colacino;J. Colas;COLLA, ALBERTO;M. Colombini;A. Corsi;J. P. Coulon;E. Cuoco;S. D'Antonio;V. Dattilo;M. Davier;R. Day;R. De Rosa;G. Debreczeni;M. Del Prete;L. Di Fiore;A. Di Lieto;Emilio Md;A. Di Virgilio;A. Dietz;M. Drago;V. Fafone;I. Ferrante;F. Fidecaro;I. Fiori;R. Flaminio;L. A. Forte;J. D. Fournier;J. Franc;FRASCA, Sergio;F. Frasconi;A. Freise;M. Galimberti;L. Gammaitoni;F. Garufi;M. E. Gaspar;G. Gemme;E. Genin;A. Gennai;A. Giazotto;R. Gouaty;M. Granata;C. Greverie;G. M. Guidi;J. F. Hayau;H. Heitmann;P. Hello;S. Hild;D. Huet;P. Jaranowskie;I. Kowalska;A. Krolak;N. Leroy;N. Letendre;L. I. Tgf;N. Liguori;M. Lorenzini;V. Loriette;G. Losurdo;E. Majorana;I. Maksimovic;N. Man;M. Mantovani;F. Marchesoni;F. Marion;J. Marque;F. Martelli;A. Masserot;C. Michel;L. Milano;Y. Minenkov;M. Mohan;N. Morgado;A. Morgia;S. Mosca;V. Moscatelli;B. Mours;F. Nocera;G. Pagliaroli;L. Palladino;C. Palomba;F. Paoletti;S. Pardi;M. Parisi;A. Pasqualetti;R. Passaquieti;D. Passuello;G. Persichetti;M. Pichot;F. Piergiovanni;M. Pietka;L. Pinard;R. Poggiani;M. Prato;G. A. Prodi;M. Punturo;P. Puppo;D. S. Rabeling;I. Racz;RAPAGNANI, Piero;V. Re;T. Regimbau;RICCI, Fulvio;F. Robinet;A. Rocchi;L. Rolland;R. Romano;D. Rosinska;P. Ruggi;B. Sassolas;D. Sentenac;L. Sperandio;R. Sturani;B. Swinkels;M. Tacca;A. Toncelli;M. Tonelli;O. Torre;E. Tournefier;F. Travasso;G. Vajente;J. F. J. Van Den Brand;S. Van Der Putten;M. Vasuth;M. Vavoulidis;G. Vedovato;D. Verkindt;F. Vetrano;A. Vicere;J. Y. Vinet;H. Vocca;R. L. Ward;M. Was;M. Yvert
2011
Abstract
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, 6 months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data and the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency domain is described and typical sensitivities measured during VSR2 are shown.
01 Pubblicazione su rivista::01a Articolo in rivista
Calibration and sensitivity of the Virgo detector during its second science run / T., Accadia; F., Acernese; F., Antonucci; P., Astone; G., Ballardin; F., Barone; M., Barsuglia; A., Basti; Th S., Bauer; M. G., Beker; A., Belletoile; S., Birindelli; M., Bitossi; M. A., Bizouard; M., Blom; F., Bondu; L., Bonelli; R., Bonnand; V., Boschi; L., Bosi; B., Bouhou; S., Braccini; C., Bradaschia; A., Brillet; V., Brisson; R., Budzynski; T., Bulik; H. J., Bulten; D., Buskulic; C., Buy; G., Cagnoli; E., Calloni; E., Campagna; B., Canuel; F., Carbognani; F., Cavalier; R., Cavalieri; G., Cella; E., Cesarini; O., Chaibi; E. C., Mottin; A., Chincarini; F., Cleva; E., Coccia; C. N., Colacino; J., Colas; Colla, Alberto; M., Colombini; A., Corsi; J. P., Coulon; E., Cuoco; S., D'Antonio; V., Dattilo; M., Davier; R., Day; R., De Rosa; G., Debreczeni; M., Del Prete; L., Di Fiore; A., Di Lieto; Emilio, Md; A., Di Virgilio; A., Dietz; M., Drago; V., Fafone; I., Ferrante; F., Fidecaro; I., Fiori; R., Flaminio; L. A., Forte; J. D., Fournier; J., Franc; Frasca, Sergio; F., Frasconi; A., Freise; M., Galimberti; L., Gammaitoni; F., Garufi; M. E., Gaspar; G., Gemme; E., Genin; A., Gennai; A., Giazotto; R., Gouaty; M., Granata; C., Greverie; G. M., Guidi; J. F., Hayau; H., Heitmann; P., Hello; S., Hild; D., Huet; P., Jaranowskie; I., Kowalska; A., Krolak; N., Leroy; N., Letendre; L. I., Tgf; N., Liguori; M., Lorenzini; V., Loriette; G., Losurdo; E., Majorana; I., Maksimovic; N., Man; M., Mantovani; F., Marchesoni; F., Marion; J., Marque; F., Martelli; A., Masserot; C., Michel; L., Milano; Y., Minenkov; M., Mohan; N., Morgado; A., Morgia; S., Mosca; V., Moscatelli; B., Mours; F., Nocera; G., Pagliaroli; L., Palladino; C., Palomba; F., Paoletti; S., Pardi; M., Parisi; A., Pasqualetti; R., Passaquieti; D., Passuello; G., Persichetti; M., Pichot; F., Piergiovanni; M., Pietka; L., Pinard; R., Poggiani; M., Prato; G. A., Prodi; M., Punturo; P., Puppo; D. S., Rabeling; I., Racz; Rapagnani, Piero; V., Re; T., Regimbau; Ricci, Fulvio; F., Robinet; A., Rocchi; L., Rolland; R., Romano; D., Rosinska; P., Ruggi; B., Sassolas; D., Sentenac; L., Sperandio; R., Sturani; B., Swinkels; M., Tacca; A., Toncelli; M., Tonelli; O., Torre; E., Tournefier; F., Travasso; G., Vajente; J. F. J., Van Den Brand; S., Van Der Putten; M., Vasuth; M., Vavoulidis; G., Vedovato; D., Verkindt; F., Vetrano; A., Vicere; J. Y., Vinet; H., Vocca; R. L., Ward; M., Was; M., Yvert. - In: CLASSICAL AND QUANTUM GRAVITY. - ISSN 0264-9381. - 28:2(2011), p. 025005. [10.1088/0264-9381/28/2/025005]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/378579
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
74
67
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.