A general procedure for the extraction of equivalent circuits from full-wave electromagnetic field numerical data is presented. The main contribution of the paper relies in a more accurate than usual deembedding technique and in the improved accuracy achieved in relevant PCB configurations with respect to existing works.
A General Procedure for the Extraction of Lumped Equivalent Circuits from Full-Wave Electromagnetic Simulations of Interconnect Discontinuities / Araneo, Rodolfo; Celozzi, Salvatore. - STAMPA. - (2003), pp. 419-424. (Intervento presentato al convegno 15th International Zurich Symposium tenutosi a Zurich nel February 18-20, 2003).
A General Procedure for the Extraction of Lumped Equivalent Circuits from Full-Wave Electromagnetic Simulations of Interconnect Discontinuities
ARANEO, Rodolfo;CELOZZI, Salvatore
2003
Abstract
A general procedure for the extraction of equivalent circuits from full-wave electromagnetic field numerical data is presented. The main contribution of the paper relies in a more accurate than usual deembedding technique and in the improved accuracy achieved in relevant PCB configurations with respect to existing works.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.