Preliminary microcalorimetric studies have been performed to analyse the response of a whole epiphytic lichen tissue (Evernia prunastri) to 2-chlorophenol (2Cl-/), a pollutant of oil mill waste-water, in order to evaluate whether the tissue might be used to assess the toxic characteristics of polluted waters. The obtained results (lichen viability expressed in hours, enthalpy variations for the 2Cl-//lichen interactions) were used to create a lichen-based biosensor that uses an amperometric oxygen electrode (a Clark electrode) as a transducer. The lichen catalyses aromatic ring cleavage (via pyrocatechase enzymes present in the lichen), and transforms aromatic substances like 2Cl-/ into muconic acid (C6H6O4). Following a full electroanalytical characterisation, the performance of the proposed lichen biosensor was compared to that of a biosensor based on Pseudomonas putida cells, which was originally constructed to monitor benzene in different matrices (water, air, petrol and oil) and was tested in our laboratory previously

Liche-based biosensor for the determination of benzene and 2-chlorophenol: microcalorimetric and amperometric investigations / Antonelli, Marta Letizia; Campanella, Luigi; Ercole, P.. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - STAMPA. - 381:(2005), pp. 1041-1048. [10.1007/s00216-004-3014-2]

Liche-based biosensor for the determination of benzene and 2-chlorophenol: microcalorimetric and amperometric investigations

ANTONELLI, Marta Letizia;CAMPANELLA, Luigi;
2005

Abstract

Preliminary microcalorimetric studies have been performed to analyse the response of a whole epiphytic lichen tissue (Evernia prunastri) to 2-chlorophenol (2Cl-/), a pollutant of oil mill waste-water, in order to evaluate whether the tissue might be used to assess the toxic characteristics of polluted waters. The obtained results (lichen viability expressed in hours, enthalpy variations for the 2Cl-//lichen interactions) were used to create a lichen-based biosensor that uses an amperometric oxygen electrode (a Clark electrode) as a transducer. The lichen catalyses aromatic ring cleavage (via pyrocatechase enzymes present in the lichen), and transforms aromatic substances like 2Cl-/ into muconic acid (C6H6O4). Following a full electroanalytical characterisation, the performance of the proposed lichen biosensor was compared to that of a biosensor based on Pseudomonas putida cells, which was originally constructed to monitor benzene in different matrices (water, air, petrol and oil) and was tested in our laboratory previously
2005
01 Pubblicazione su rivista::01a Articolo in rivista
Liche-based biosensor for the determination of benzene and 2-chlorophenol: microcalorimetric and amperometric investigations / Antonelli, Marta Letizia; Campanella, Luigi; Ercole, P.. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - STAMPA. - 381:(2005), pp. 1041-1048. [10.1007/s00216-004-3014-2]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/241529
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact