Objective To assess noise exposure during noninvasive ventilation (NIV) with different types of interface (helmet, nasal, and facial masks). Subjects and methods Ten naive healthy volunteers underwent NIV at pressure support levels of 10 and 15 cmH2O with: (a) helmet, (b) helmet equipped with HME filters at the junctions between the helmet and the inspiratory and expiratory branches of the respiratory circuit, (c) nasal mask, and (d) facial mask. Noise intensity was assessed with a sound level meter by placing a microphone near the right ear. Noise intensity and degree of discomfort were also assessed subjectively with a visual analogue scale. Results Inside the helmet noise exceeded 100 dB. Noise intensity was poorly affected by pressure support level and unaffected by the presence of HME filters. During NIV with nasal or facial masks the noise did not exceed 70 dB (i.e., noise was not louder than the usual noise background in ICU). Subjective evaluation of noise intensity mirrored objective measurements; however, the presence of HME filters was associated with the feeling of less noise inside the helmet. The discomfort associated with the helmet did not significantly differ from that associated with the masks. Conclusions NIV helmet is associated with significantly greater noise than nasal and facial masks, but is as comfortable as masks, at least in the short term. Medium- and long-term exposure to loud noise may potentially impair ear function and increase the patients discomfort.

Noise exposure during non invasive ventiltion with a melme, a nasal mask, and a facial mask / Cavaliere, Francesco; G., Conti; R., Costa; R., Proietti; Sciuto, Antonino; Masieri, Simonetta. - In: INTENSIVE CARE MEDICINE. - ISSN 0342-4642. - STAMPA. - 30(9):(2004), pp. 1755-1760. [10.1007/s00134-004-2347-9]

Noise exposure during non invasive ventiltion with a melme, a nasal mask, and a facial mask.

SCIUTO, Antonino;MASIERI, Simonetta
2004

Abstract

Objective To assess noise exposure during noninvasive ventilation (NIV) with different types of interface (helmet, nasal, and facial masks). Subjects and methods Ten naive healthy volunteers underwent NIV at pressure support levels of 10 and 15 cmH2O with: (a) helmet, (b) helmet equipped with HME filters at the junctions between the helmet and the inspiratory and expiratory branches of the respiratory circuit, (c) nasal mask, and (d) facial mask. Noise intensity was assessed with a sound level meter by placing a microphone near the right ear. Noise intensity and degree of discomfort were also assessed subjectively with a visual analogue scale. Results Inside the helmet noise exceeded 100 dB. Noise intensity was poorly affected by pressure support level and unaffected by the presence of HME filters. During NIV with nasal or facial masks the noise did not exceed 70 dB (i.e., noise was not louder than the usual noise background in ICU). Subjective evaluation of noise intensity mirrored objective measurements; however, the presence of HME filters was associated with the feeling of less noise inside the helmet. The discomfort associated with the helmet did not significantly differ from that associated with the masks. Conclusions NIV helmet is associated with significantly greater noise than nasal and facial masks, but is as comfortable as masks, at least in the short term. Medium- and long-term exposure to loud noise may potentially impair ear function and increase the patients discomfort.
2004
Non invasive ventilation - Helmet - Nasal mask - Facial mask - Noise exposure
01 Pubblicazione su rivista::01a Articolo in rivista
Noise exposure during non invasive ventiltion with a melme, a nasal mask, and a facial mask / Cavaliere, Francesco; G., Conti; R., Costa; R., Proietti; Sciuto, Antonino; Masieri, Simonetta. - In: INTENSIVE CARE MEDICINE. - ISSN 0342-4642. - STAMPA. - 30(9):(2004), pp. 1755-1760. [10.1007/s00134-004-2347-9]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/241157
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 40
social impact