Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
The performances of the longitudinal sensing and control system of the Virgo gravitational wave detector are described. This system is able to stably maintain the RMS residual fluctuation of the interferometer longitudinal degrees of freedom around or below 10(-11) m, compatible with the original Virgo requirements. Moreover the detector sensitivity is not limited by longitudinal control noise at any frequency. Indeed the noise re-introduced by the longitudinal control system does not affect the Virgo design sensitivity. (C) 2009 Elsevier B.V. All rights reserved.
Performances of the Virgo interferometer longitudinal control system / Acernese, F.; Antonucci, F.; Aoudia, S.; Arun, K. G.; Astone, P.; Ballardin, G.; Barone, F.; Barsuglia, M.; Bauer, Th S.; Beker, M. G.; Bigotta, S.; Birindelli, S.; Bizouard, M. A.; Blom, M.; Boccara, C.; Bondu, F.; Bonelli, L.; Bosi, L.; Braccini, S.; Bradaschia, C.; Brillet, A.; Brisson, V.; Budzynski, R.; Bulik, T.; Bulten, H. J.; Buskulic, D.; Cagnoli, G.; Calloni, E.; Campagna, E.; Canuel, B.; Carbognani, F.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cesarini, E.; Chassande Mottin, E.; Chincarini, A.; Cleva, F.; Coccia, E.; Colacino, C. N.; Colas, J.; Colla, A.; Colombini, M.; Corda, C.; Corsi, A.; Coulon, J. P.; Cuoco, E.; D'Antonio, S.; Dari, A.; Dattilo, V.; Davier, M.; Day, R.; De Rosa, R.; Del Prete, M.; Di Fiore, L.; Di Lieto, A.; Emilio, Md; Di Virgilio, A.; Dietz, A.; Drago, M.; Fafone, V.; Ferrante, I.; Fidecaro, F.; Fiori, I.; Flaminio, R.; Fournier, J. D.; Franc, J.; Frasca, Sergio; Frasconi, F.; Freise, A.; Gammaitoni, L.; Garufi, F.; Gemme, G.; Genin, E.; Gennai, A.; Giazotto, A.; Granata, M.; Greverie, C.; Guidi, G.; Heitmann, H.; Hello, P.; Hild, S.; Huet, D.; Jaranowski, P.; Kowalska, I.; Krolak, A.; La Penna, P.; Leroy, N.; Letendre, N.; Tgf, L. I.; Lorenzini, M.; Loriette, V.; Losurdo, G.; Mackowski, J. M.; Majorana, E.; Man, N.; Mantovani, M.; Marchesoni, F.; Marion, F.; Marque, J.; Martelli, F.; Masserot, A.; Menzinger, F.; Michel, C.; Milano, L.; Minenkov, Y.; Mohan, M.; Moreau, J.; Morgado, N.; Morgia, A.; Mosca, S.; Moscatelli, V.; Mours, B.; Neri, I.; Nocera, F.; Pagliaroli, G.; Palomba, C.; Paoletti, F.; Pardi, S.; Parisi, M.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Persichetti, G.; Pichot, M.; Piergiovanni, F.; Pietka, M.; Pinard, L.; Poggiani, R.; Prato, M.; Prodi, G. A.; Punturo, M.; Puppo, P.; Rabaste, O.; Rabeling, D. S.; Rapagnani, Piero; Re, V.; Regimbau, T.; Ricci, Fulvio; Robinet, F.; Rocchi, A.; Rolland, L.; Romano, R.; Rosinska, D.; Ruggi, P.; Salemi, F.; Sassolas, B.; Sentenac, D.; Sturani, R.; Swinkels, B.; Toncelli, A.; Tonelli, M.; Tournefier, E.; Travasso, F.; Trummer, J.; Vajente, G.; Jfj Van Den Brandy, ; Van Der Putten, S.; Vavoulidis, M.; Vedovato, G.; Verkindt, D.; Vetrano, F.; Vicere, A.; Vinet, J. Y.; Vocca, H.; Was, M.; Yvert, M.. - In: ASTROPARTICLE PHYSICS. - ISSN 0927-6505. - 33:2(2010), pp. 75-80. [10.1016/j.astropartphys.2009.11.006]
Performances of the Virgo interferometer longitudinal control system
F. Acernese;F. Antonucci;S. Aoudia;K. G. Arun;P. Astone;G. Ballardin;F. Barone;M. Barsuglia;Th S. Bauer;M. G. Beker;S. Bigotta;S. Birindelli;M. A. Bizouard;M. Blom;C. Boccara;F. Bondu;L. Bonelli;L. Bosi;S. Braccini;C. Bradaschia;A. Brillet;V. Brisson;R. Budzynski;T. Bulik;H. J. Bulten;D. Buskulic;G. Cagnoli;E. Calloni;E. Campagna;B. Canuel;F. Carbognani;F. Cavalier;R. Cavalieri;G. Cella;E. Cesarini;E. Chassande Mottin;A. Chincarini;F. Cleva;E. Coccia;C. N. Colacino;J. Colas;A. Colla;M. Colombini;C. Corda;A. Corsi;J. P. Coulon;E. Cuoco;S. D'Antonio;A. Dari;V. Dattilo;M. Davier;R. Day;R. De Rosa;M. Del Prete;L. Di Fiore;A. Di Lieto;Emilio Md;A. Di Virgilio;A. Dietz;M. Drago;V. Fafone;I. Ferrante;F. Fidecaro;I. Fiori;R. Flaminio;J. D. Fournier;J. Franc;FRASCA, Sergio;F. Frasconi;A. Freise;L. Gammaitoni;F. Garufi;G. Gemme;E. Genin;A. Gennai;A. Giazotto;M. Granata;C. Greverie;G. Guidi;H. Heitmann;P. Hello;S. Hild;D. Huet;P. Jaranowski;I. Kowalska;A. Krolak;P. La Penna;N. Leroy;N. Letendre;L. I. Tgf;M. Lorenzini;V. Loriette;G. Losurdo;J. M. Mackowski;E. Majorana;N. Man;M. Mantovani;F. Marchesoni;F. Marion;J. Marque;F. Martelli;A. Masserot;F. Menzinger;C. Michel;L. Milano;Y. Minenkov;M. Mohan;J. Moreau;N. Morgado;A. Morgia;S. Mosca;V. Moscatelli;B. Mours;I. Neri;F. Nocera;G. Pagliaroli;C. Palomba;F. Paoletti;S. Pardi;M. Parisi;A. Pasqualetti;R. Passaquieti;D. Passuello;G. Persichetti;M. Pichot;F. Piergiovanni;M. Pietka;L. Pinard;R. Poggiani;M. Prato;G. A. Prodi;M. Punturo;P. Puppo;O. Rabaste;D. S. Rabeling;RAPAGNANI, Piero;V. Re;T. Regimbau;RICCI, Fulvio;F. Robinet;A. Rocchi;L. Rolland;R. Romano;D. Rosinska;P. Ruggi;F. Salemi;B. Sassolas;D. Sentenac;R. Sturani;B. Swinkels;A. Toncelli;M. Tonelli;E. Tournefier;F. Travasso;J. Trummer;G. Vajente;Jfj Van Den Brandy;S. Van Der Putten;M. Vavoulidis;G. Vedovato;D. Verkindt;F. Vetrano;A. Vicere;J. Y. Vinet;H. Vocca;M. Was;M. Yvert
2010
Abstract
The performances of the longitudinal sensing and control system of the Virgo gravitational wave detector are described. This system is able to stably maintain the RMS residual fluctuation of the interferometer longitudinal degrees of freedom around or below 10(-11) m, compatible with the original Virgo requirements. Moreover the detector sensitivity is not limited by longitudinal control noise at any frequency. Indeed the noise re-introduced by the longitudinal control system does not affect the Virgo design sensitivity. (C) 2009 Elsevier B.V. All rights reserved.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/226576
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
11
8
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.