Objective The objective was to demonstrate the feasibility of ascending thoracic endovascular aortic repair (a-TEVAR) as a minimally invasive treatment for an ascending anastomotic pseudoaneurysm in a patient unsuitable for redo open surgery. Key Steps The steps included: 1) multidisciplinary evaluation and detailed computed tomography angiography–based anatomical planning; 2) assessment of proximal and distal landing zones, coronary ostia, and supra-aortic vessel anatomy; 3) selection of a Gore C-TAG endograft based on anatomical suitability; 4) percutaneous transfemoral a-TEVAR under rapid ventricular pacing with intraoperative angiographic guidance; and 5) confirmation of complete pseudoaneurysm exclusion while preserving coronary and supra-aortic vessel patency, followed by serial computed tomography angiography surveillance. Potential Pitfalls Limited landing zones, proximity to the coronary ostia and supra-aortic vessels, inaccurate device deployment, and the absence of dedicated ascending aortic devices increase procedural complexity. Careful patient selection, meticulous preoperative planning, and rapid ventricular pacing are essential to minimize these risks. Take-Home Messages The a-TEVAR procedure is a feasible alternative to high-risk redo sternotomy in carefully selected patients with favorable anatomy. However, a-TEVAR of the ascending aorta continues to pose significant technical and clinical challenges, and further investigations are needed.

Endovascular Solution for Anastomotic Pseudoaneurysm of the Ascending Aorta / Margheritini, C., Coli, M., Colonna, G., Battocchio, C., Capuano, F., Berni, A., Rossi, M., Rizzo, L., Melina, G., Sirignano, P.. - (2026). [10.1016/j.jaccas.2026.110218]

Endovascular Solution for Anastomotic Pseudoaneurysm of the Ascending Aorta

costanza margheritini;marco coli
Primo
;
g. colonna;c. battocchio;f. capuano;A. berni;L. rizzo;G. melina;P. sirignano
2026

Abstract

Objective The objective was to demonstrate the feasibility of ascending thoracic endovascular aortic repair (a-TEVAR) as a minimally invasive treatment for an ascending anastomotic pseudoaneurysm in a patient unsuitable for redo open surgery. Key Steps The steps included: 1) multidisciplinary evaluation and detailed computed tomography angiography–based anatomical planning; 2) assessment of proximal and distal landing zones, coronary ostia, and supra-aortic vessel anatomy; 3) selection of a Gore C-TAG endograft based on anatomical suitability; 4) percutaneous transfemoral a-TEVAR under rapid ventricular pacing with intraoperative angiographic guidance; and 5) confirmation of complete pseudoaneurysm exclusion while preserving coronary and supra-aortic vessel patency, followed by serial computed tomography angiography surveillance. Potential Pitfalls Limited landing zones, proximity to the coronary ostia and supra-aortic vessels, inaccurate device deployment, and the absence of dedicated ascending aortic devices increase procedural complexity. Careful patient selection, meticulous preoperative planning, and rapid ventricular pacing are essential to minimize these risks. Take-Home Messages The a-TEVAR procedure is a feasible alternative to high-risk redo sternotomy in carefully selected patients with favorable anatomy. However, a-TEVAR of the ascending aorta continues to pose significant technical and clinical challenges, and further investigations are needed.
2026
Aortic pseudoaneurysm
01 Pubblicazione su rivista::01i Case report
Endovascular Solution for Anastomotic Pseudoaneurysm of the Ascending Aorta / Margheritini, C., Coli, M., Colonna, G., Battocchio, C., Capuano, F., Berni, A., Rossi, M., Rizzo, L., Melina, G., Sirignano, P.. - (2026). [10.1016/j.jaccas.2026.110218]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1781144
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact