AIM: The aim of the present study was to evaluate the accuracy of dynamic navigation (DN) in miniscrew insertion in the palatal vault by comparing the deviation between planned and placed miniscrew positions. The secondary outcome was to evaluate the correlation between the number of miniscrews inserted and both the accuracy variables and the duration of interventions. MATERIALS AND METHODS: Twenty-three subjects were included in the study and each had two miniscrews inserted using a DN system (46 miniscrews inserted overall). Preoperative STL and DICOM files were matched to planned miniscrews insertion and a postoperative CBCT was performed immediately afterward to measure the deviations between the planned and placed miniscrews, evaluating four variables: Entry-3D, Apex-3D, Apex-vertical, and angular deviation. The duration of intervention was also calculated. Descriptive statistics and Pearson correlation coefficient were performed; the P value was set at ≤ 0.05. RESULTS: The mean Entry-3D deviation was 2.55 mm; the mean Apex-3D deviation was 3.11 mm; the mean Apex-vertical deviation was 0.87 mm; and the mean angular deviation was 8.50 degrees. The mean duration of the intervention was 2:75 min:sec. A statistically significant correlation was found only between the number of surgeries and the duration of the interventions, which decreased over time. CONCLUSIONS: It is possible to conclude that DN is a viable alternative to miniscrew insertion in the palatal vault even if there is a wide deviation range. There is no significant correlation between the accuracy variables and the number of surgeries. In contrast, the duration of the interventions shortens over time.

Dynamic navigation system accuracy in orthodontic miniscrew insertion in the palatal vault: a prospective single-arm clinical study / Brilli, Davide; Giansanti, Matteo; Bertoldo, Serena; Cauli, Isabella; Cassetta, Michele. - In: INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY. - ISSN 1463-4201. - 29:1(2026), pp. 23-31. [10.3290/j.ijcd.b6329377]

Dynamic navigation system accuracy in orthodontic miniscrew insertion in the palatal vault: a prospective single-arm clinical study

Giansanti, Matteo
Investigation
;
Bertoldo, Serena
Investigation
;
Cauli, Isabella
Investigation
;
Cassetta, Michele
Writing – Review & Editing
2026

Abstract

AIM: The aim of the present study was to evaluate the accuracy of dynamic navigation (DN) in miniscrew insertion in the palatal vault by comparing the deviation between planned and placed miniscrew positions. The secondary outcome was to evaluate the correlation between the number of miniscrews inserted and both the accuracy variables and the duration of interventions. MATERIALS AND METHODS: Twenty-three subjects were included in the study and each had two miniscrews inserted using a DN system (46 miniscrews inserted overall). Preoperative STL and DICOM files were matched to planned miniscrews insertion and a postoperative CBCT was performed immediately afterward to measure the deviations between the planned and placed miniscrews, evaluating four variables: Entry-3D, Apex-3D, Apex-vertical, and angular deviation. The duration of intervention was also calculated. Descriptive statistics and Pearson correlation coefficient were performed; the P value was set at ≤ 0.05. RESULTS: The mean Entry-3D deviation was 2.55 mm; the mean Apex-3D deviation was 3.11 mm; the mean Apex-vertical deviation was 0.87 mm; and the mean angular deviation was 8.50 degrees. The mean duration of the intervention was 2:75 min:sec. A statistically significant correlation was found only between the number of surgeries and the duration of the interventions, which decreased over time. CONCLUSIONS: It is possible to conclude that DN is a viable alternative to miniscrew insertion in the palatal vault even if there is a wide deviation range. There is no significant correlation between the accuracy variables and the number of surgeries. In contrast, the duration of the interventions shortens over time.
2026
CBCT; TADs; computer-guided surgery; digital dentistry; dynamic navigation; miniscrew
01 Pubblicazione su rivista::01a Articolo in rivista
Dynamic navigation system accuracy in orthodontic miniscrew insertion in the palatal vault: a prospective single-arm clinical study / Brilli, Davide; Giansanti, Matteo; Bertoldo, Serena; Cauli, Isabella; Cassetta, Michele. - In: INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY. - ISSN 1463-4201. - 29:1(2026), pp. 23-31. [10.3290/j.ijcd.b6329377]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1766912
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact