Objective Image Quality Assessment (IQA) methods often lack of linearity of their quality estimates with respect to scores expressed by human subjects and therefore IQA metrics undergo a calibration process based on subjective quality examples. However, example-based training presents a challenge in terms of generalization hampering result comparison across different applications and operative conditions. In this paper, new Full Reference (FR) techniques, providing estimates linearly correlated with human scores without using calibration are introduced. We show that on natural images, application of estimation theory and psychophysical principles to images degraded by Gaussian blur leads to a so-called canonical IQA method, whose estimates are linearly correlated to both the subjective scores and the viewing distance. Then, we show that any mainstream IQA methods can be reconducted to the canonical method by converting its metric based on a unique specimen image. The proposed scheme is extended to wide classes of degraded images, e.g. noisy and compressed images. The resulting calibration-free FR IQA methods allows for comparability and interoperability across different imaging systems and on different viewing distances. A comparison of their statistical performance with respect to state-of-the-art calibration prone methods is finally provided, showing that the presented model is a valid alternative to the final 5-parameter calibration step of IQA methods, and the two parameters of the model have a clear operational meaning and are simply determined in practical applications. The enhanced performance are achieved across multiple viewing distance databases by independently realigning the blur values associated with each distance.

Full-reference calibration-free image quality assessment / Giannitrapani, Paolo; Di Claudio, Elio D.; Iacovitti, Giovanni. - In: SIGNAL PROCESSING-IMAGE COMMUNICATION. - ISSN 0923-5965. - 130:(2024). [10.1016/j.image.2024.117212]

Full-reference calibration-free image quality assessment

Paolo Giannitrapani
Primo
Conceptualization
;
Elio D. Di Claudio
Secondo
Supervision
;
Giovanni Iacovitti
Ultimo
Conceptualization
2024

Abstract

Objective Image Quality Assessment (IQA) methods often lack of linearity of their quality estimates with respect to scores expressed by human subjects and therefore IQA metrics undergo a calibration process based on subjective quality examples. However, example-based training presents a challenge in terms of generalization hampering result comparison across different applications and operative conditions. In this paper, new Full Reference (FR) techniques, providing estimates linearly correlated with human scores without using calibration are introduced. We show that on natural images, application of estimation theory and psychophysical principles to images degraded by Gaussian blur leads to a so-called canonical IQA method, whose estimates are linearly correlated to both the subjective scores and the viewing distance. Then, we show that any mainstream IQA methods can be reconducted to the canonical method by converting its metric based on a unique specimen image. The proposed scheme is extended to wide classes of degraded images, e.g. noisy and compressed images. The resulting calibration-free FR IQA methods allows for comparability and interoperability across different imaging systems and on different viewing distances. A comparison of their statistical performance with respect to state-of-the-art calibration prone methods is finally provided, showing that the presented model is a valid alternative to the final 5-parameter calibration step of IQA methods, and the two parameters of the model have a clear operational meaning and are simply determined in practical applications. The enhanced performance are achieved across multiple viewing distance databases by independently realigning the blur values associated with each distance.
2024
image quality assessment; psycho-visual calibration; perceptual equivalence; positional fisher information; viewing distance
01 Pubblicazione su rivista::01a Articolo in rivista
Full-reference calibration-free image quality assessment / Giannitrapani, Paolo; Di Claudio, Elio D.; Iacovitti, Giovanni. - In: SIGNAL PROCESSING-IMAGE COMMUNICATION. - ISSN 0923-5965. - 130:(2024). [10.1016/j.image.2024.117212]
File allegati a questo prodotto
File Dimensione Formato  
Giannitrapani_Full-reference_2024.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.93 MB
Formato Adobe PDF
4.93 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1724329
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact