Catheter dislocation and fracture with migration of central venous lines have been reported in the International literature. Catheter fracture with consequent migration has been observed in 0.5-3.0% and may either be consequent to catheter removal or it can occur spontane-ously. Our case report concerns the migration of a Hickman catheter connected to a venous port to the right atrium in a 61-year old patient. A literature up-to-date has been performed to assess the risk of port-a-cath positioning. The position of catheter tip is considered critical for the risk of migration, that is greater as higher the tip localization respect to the carina. The aim of our study is to underline the critical role of X-ray to visualize the exact location of the catheter tip, regard-less of the approach used for catheter positioning.
Fracture and migration in right atrium of a permanent venous central access system in a elderly patient: case report and literature review / Gazzanelli, S; Miccini, M; Sapienza, P; Cavallaro, G; Biacchi, D; Crocetti, D; Fiori, E; Sammartino, P; Guerra, C; Ranieri, M. - In: LA CLINICA TERAPEUTICA. - ISSN 1972-6007. - 173:3(2022), pp. 207-213. [10.7417/CT.2022.2419]
Fracture and migration in right atrium of a permanent venous central access system in a elderly patient: case report and literature review
S Gazzanelli
;M Miccini;P Sapienza;G Cavallaro;D Biacchi;D Crocetti;E Fiori;P Sammartino;C Guerra;M Ranieri
2022
Abstract
Catheter dislocation and fracture with migration of central venous lines have been reported in the International literature. Catheter fracture with consequent migration has been observed in 0.5-3.0% and may either be consequent to catheter removal or it can occur spontane-ously. Our case report concerns the migration of a Hickman catheter connected to a venous port to the right atrium in a 61-year old patient. A literature up-to-date has been performed to assess the risk of port-a-cath positioning. The position of catheter tip is considered critical for the risk of migration, that is greater as higher the tip localization respect to the carina. The aim of our study is to underline the critical role of X-ray to visualize the exact location of the catheter tip, regard-less of the approach used for catheter positioning.File | Dimensione | Formato | |
---|---|---|---|
Gazzanelli_Fracture-and-migration_2022.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
166.92 kB
Formato
Adobe PDF
|
166.92 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.