In the framework of the OECD/NEA/CSNI/WGAMA, an activity on the “Status report on thermal–hydraulic passive systems design and safety assessment” has been conducted. Within this activity, a benchmark exercise, based on the experimental data developed in the full scale PERSEO (in-Pool Energy Removal System for Emergency Operation) component separate effect test facility, built at SIET (Piacenza, Italy), has been proposed and carried out. An “OPEN” benchmark exercise, hosted by ENEA, has been conducted. Twelve results from eleven Organizations were submitted. PERSEO is a full-scale separate effect test facility designed to study a new passive decay heat removal system operating in natural circulation. Test 7 is a full pressure test (7 MPa) and investigates the system stability and the system operation. The accuracy of the calculated results has been evaluated both qualitatively and quantitatively. The latter has been conducted adopting the Fast Fourier Transform Based Method. The present paper summarizes the main features of the PERSEO facility and Test 7 and discusses the main results and outcome of the benchmark exercise.
OECD/NEA/CSNI/WGAMA PERSEO benchmark. Main outcomes and conclusions / Mascari, F.; Bersano, A.; Alcaro, F.; Stempniewicz, M.; Albright, L.; Jevremovic, T.; Andrews, N.; Gauntt, R.; Austregesilo, H.; Buchholz, S.; Bellomo, A.; D'Auria, F.; Di Palma, G.; Lanfredini, M.; Spina, G.; Bertani, C.; De Salve, M.; Falcone, N.; Caruso, G.; Giannetti, F.; Narcisi, V.; Choi, C.; Ha, K.; Jeon, B. G.; Kang, K. H.; Kim, K.; Park, H. S.; Karppinen, I.; Lahovsky, L. F.; Meca, R.; Parduba, Z.; Lien, P. H.; Tomashchik, D. Y.; Burgazzi, L.; Lombardo, C.; Meloni, P.; Ferri, R.. - In: NUCLEAR ENGINEERING AND DESIGN. - ISSN 0029-5493. - 405:(2023), pp. 1-12. [10.1016/j.nucengdes.2023.112220]
OECD/NEA/CSNI/WGAMA PERSEO benchmark. Main outcomes and conclusions
Caruso G.;Giannetti F.;Narcisi V.;
2023
Abstract
In the framework of the OECD/NEA/CSNI/WGAMA, an activity on the “Status report on thermal–hydraulic passive systems design and safety assessment” has been conducted. Within this activity, a benchmark exercise, based on the experimental data developed in the full scale PERSEO (in-Pool Energy Removal System for Emergency Operation) component separate effect test facility, built at SIET (Piacenza, Italy), has been proposed and carried out. An “OPEN” benchmark exercise, hosted by ENEA, has been conducted. Twelve results from eleven Organizations were submitted. PERSEO is a full-scale separate effect test facility designed to study a new passive decay heat removal system operating in natural circulation. Test 7 is a full pressure test (7 MPa) and investigates the system stability and the system operation. The accuracy of the calculated results has been evaluated both qualitatively and quantitatively. The latter has been conducted adopting the Fast Fourier Transform Based Method. The present paper summarizes the main features of the PERSEO facility and Test 7 and discusses the main results and outcome of the benchmark exercise.File | Dimensione | Formato | |
---|---|---|---|
Mascari_OECD/NEA/CSNI/WGAMA PERSEO_post print_2023.pdf.pdf
embargo fino al 01/05/2025
Note: post-print
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Creative commons
Dimensione
902.39 kB
Formato
Adobe PDF
|
902.39 kB | Adobe PDF | Contatta l'autore |
Mascari_OECD/NEA/CSNI/WGAMA PERSEO_2023.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
2.7 MB
Formato
Adobe PDF
|
2.7 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.