Mitral regurgitation is a challenging condition, especially in patients at high risk for open heart surgery. Nowadays, trans-catheter procedures for treatment of valvular disorders represent a valid alternative to traditional surgical techniques. These include not only the trans-catheter valve implants but also other percutaneous devices used to repair native valves, notably mitral valve. However, in case of failure, mis-placement, or unsatisfactory results of percutaneous devices, explant and correction of the valvular disease may be required. In such scenarios, only traditional surgery techniques can be efficacious. A case of Cardioband System (Edwards Lifescience, Irvine, CA, USA) surgical explant and valve replacement for persisting mitral valve regurgitation is reported. The technical details and pitfalls of the surgical removal procedure are discussed.

Cardioband removal for secondary mitral valve regurgitation: pitfall and surgical technique / Pisani, A.; Poitier, B.; Borghese, O.; Braham, W.; Alkhoder, S.; Ghodbane, W.. - In: INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY. - ISSN 0970-9134. - 37:6(2021), pp. 684-687. [10.1007/s12055-021-01202-4]

Cardioband removal for secondary mitral valve regurgitation: pitfall and surgical technique

Pisani A.;Borghese O.;
2021

Abstract

Mitral regurgitation is a challenging condition, especially in patients at high risk for open heart surgery. Nowadays, trans-catheter procedures for treatment of valvular disorders represent a valid alternative to traditional surgical techniques. These include not only the trans-catheter valve implants but also other percutaneous devices used to repair native valves, notably mitral valve. However, in case of failure, mis-placement, or unsatisfactory results of percutaneous devices, explant and correction of the valvular disease may be required. In such scenarios, only traditional surgery techniques can be efficacious. A case of Cardioband System (Edwards Lifescience, Irvine, CA, USA) surgical explant and valve replacement for persisting mitral valve regurgitation is reported. The technical details and pitfalls of the surgical removal procedure are discussed.
2021
Annuloplasty; Mitral valve annulus repair; Mitral valve regurgitation
01 Pubblicazione su rivista::01i Case report
Cardioband removal for secondary mitral valve regurgitation: pitfall and surgical technique / Pisani, A.; Poitier, B.; Borghese, O.; Braham, W.; Alkhoder, S.; Ghodbane, W.. - In: INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY. - ISSN 0970-9134. - 37:6(2021), pp. 684-687. [10.1007/s12055-021-01202-4]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1670378
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact