Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequencydependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give higher flexibility to the insulation coordination study. In such a case, a dilemma rises up when a frequency shall be selected for the determination of the cable parameters. In this study, a comparative analysis between the two models has been performed considering a typical configuration layout, i.e. an overvoltage coming from an overhead line and stressing the cable line terminated on a transformer. The overvoltages stressing both cable insulation wall and cable thermoplastic jacket are evaluated using the same system configuration with both frequency-dependent and distributed parameter with lumped losses power cable line models, in the latter case sweeping different frequency values for the determination of the cable parameters. A frequency range that minimise the differences between the overvoltage estimation using the two models is suggested.

Comparing frequency-dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages / Marzinotto, Massimo; Pelliccione, Giuseppe. - In: IET SCIENCE, MEASUREMENT & TECHNOLOGY. - ISSN 1751-8822. - 13:2(2019), pp. 115-122. [10.1049/iet-smt.2018.5118]

Comparing frequency-dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages

Massimo Marzinotto
Conceptualization
;
Giuseppe Pelliccione
Conceptualization
2019

Abstract

Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequencydependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give higher flexibility to the insulation coordination study. In such a case, a dilemma rises up when a frequency shall be selected for the determination of the cable parameters. In this study, a comparative analysis between the two models has been performed considering a typical configuration layout, i.e. an overvoltage coming from an overhead line and stressing the cable line terminated on a transformer. The overvoltages stressing both cable insulation wall and cable thermoplastic jacket are evaluated using the same system configuration with both frequency-dependent and distributed parameter with lumped losses power cable line models, in the latter case sweeping different frequency values for the determination of the cable parameters. A frequency range that minimise the differences between the overvoltage estimation using the two models is suggested.
2019
power cable line models; insulation coordination; overvoltages
01 Pubblicazione su rivista::01a Articolo in rivista
Comparing frequency-dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages / Marzinotto, Massimo; Pelliccione, Giuseppe. - In: IET SCIENCE, MEASUREMENT & TECHNOLOGY. - ISSN 1751-8822. - 13:2(2019), pp. 115-122. [10.1049/iet-smt.2018.5118]
File allegati a questo prodotto
File Dimensione Formato  
Marzinotto_Comparing-frequency-dependent_2019.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 3.31 MB
Formato Adobe PDF
3.31 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1670197
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact