Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequencydependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give higher flexibility to the insulation coordination study. In such a case, a dilemma rises up when a frequency shall be selected for the determination of the cable parameters. In this study, a comparative analysis between the two models has been performed considering a typical configuration layout, i.e. an overvoltage coming from an overhead line and stressing the cable line terminated on a transformer. The overvoltages stressing both cable insulation wall and cable thermoplastic jacket are evaluated using the same system configuration with both frequency-dependent and distributed parameter with lumped losses power cable line models, in the latter case sweeping different frequency values for the determination of the cable parameters. A frequency range that minimise the differences between the overvoltage estimation using the two models is suggested.
Comparing frequency-dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages / Marzinotto, Massimo; Pelliccione, Giuseppe. - In: IET SCIENCE, MEASUREMENT & TECHNOLOGY. - ISSN 1751-8822. - 13:2(2019), pp. 115-122. [10.1049/iet-smt.2018.5118]
Comparing frequency-dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages
Massimo Marzinotto
Conceptualization
;Giuseppe PelliccioneConceptualization
2019
Abstract
Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequencydependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give higher flexibility to the insulation coordination study. In such a case, a dilemma rises up when a frequency shall be selected for the determination of the cable parameters. In this study, a comparative analysis between the two models has been performed considering a typical configuration layout, i.e. an overvoltage coming from an overhead line and stressing the cable line terminated on a transformer. The overvoltages stressing both cable insulation wall and cable thermoplastic jacket are evaluated using the same system configuration with both frequency-dependent and distributed parameter with lumped losses power cable line models, in the latter case sweeping different frequency values for the determination of the cable parameters. A frequency range that minimise the differences between the overvoltage estimation using the two models is suggested.File | Dimensione | Formato | |
---|---|---|---|
Marzinotto_Comparing-frequency-dependent_2019.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
3.31 MB
Formato
Adobe PDF
|
3.31 MB | Adobe PDF |