The EU-DEMO Water-Cooled Lithium-Lead (WCLL) Breeding Blanket (BB) main subsystems to be cooled are the Breeder Zone (BZ) and the First Wall (FW). Each subsystem will be equipped with an independent Primary Heat Transfer System (PHTS). Within the framework of the EUROfusion Work Package Breeding Blanket research program, several accidents belonging to the category of “Decrease in Coolant System Flow Rate” were studied. The activity was aimed at evaluating the blanket and primary cooling systems thermal-hydraulic performances during such transient conditions. A complete model including the BB and related PHTS circuits has been developed at Sapienza University of Rome. A modified version of RELAP5/Mod3.3 system code has been used to perform the calculations. The simulation results showed that a locked rotor/shaft seizure of a BZ or a FW main coolant pump is the most challenging scenario. BZ and FW system behavior has been analyzed following this initiating event with the goal of the design improvement and to individuate the need for preventive measures. The influence of loss of off-site power on the accident evolution has also been investigated. Moreover, management strategies have been proposed for different reactor components. Calculations demonstrate that the current blanket and PHTS design is appropriate to cope with these kinds of accident scenarios.

Transient analysis of a locked rotor/shaft seizure accident involving the EU-DEMO WCLL Breeding Blanket primary cooling circuits / Ciurluini, C.; D'Onorio, M.; Giannetti, F.; Caruso, G.; Del Nevo, A.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 187:(2023), pp. 1-12. [10.1016/j.fusengdes.2022.113396]

Transient analysis of a locked rotor/shaft seizure accident involving the EU-DEMO WCLL Breeding Blanket primary cooling circuits

C. Ciurluini
Primo
;
M. D'Onorio
Secondo
;
F. Giannetti;G. Caruso
Penultimo
;
2023

Abstract

The EU-DEMO Water-Cooled Lithium-Lead (WCLL) Breeding Blanket (BB) main subsystems to be cooled are the Breeder Zone (BZ) and the First Wall (FW). Each subsystem will be equipped with an independent Primary Heat Transfer System (PHTS). Within the framework of the EUROfusion Work Package Breeding Blanket research program, several accidents belonging to the category of “Decrease in Coolant System Flow Rate” were studied. The activity was aimed at evaluating the blanket and primary cooling systems thermal-hydraulic performances during such transient conditions. A complete model including the BB and related PHTS circuits has been developed at Sapienza University of Rome. A modified version of RELAP5/Mod3.3 system code has been used to perform the calculations. The simulation results showed that a locked rotor/shaft seizure of a BZ or a FW main coolant pump is the most challenging scenario. BZ and FW system behavior has been analyzed following this initiating event with the goal of the design improvement and to individuate the need for preventive measures. The influence of loss of off-site power on the accident evolution has also been investigated. Moreover, management strategies have been proposed for different reactor components. Calculations demonstrate that the current blanket and PHTS design is appropriate to cope with these kinds of accident scenarios.
2023
DEMO; primary heat transfer system; balance of plant; RELAP5; accident analysis
01 Pubblicazione su rivista::01a Articolo in rivista
Transient analysis of a locked rotor/shaft seizure accident involving the EU-DEMO WCLL Breeding Blanket primary cooling circuits / Ciurluini, C.; D'Onorio, M.; Giannetti, F.; Caruso, G.; Del Nevo, A.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 187:(2023), pp. 1-12. [10.1016/j.fusengdes.2022.113396]
File allegati a questo prodotto
File Dimensione Formato  
Ciurluini_Transient analysis_2023.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 5.9 MB
Formato Adobe PDF
5.9 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1663434
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact