The aim of this human cadaver study was to assess the accuracy of zygomatic/pterygoid implant placement using custom-made bone-supported laser sintered titanium templates. For this purpose, pre-surgical planning was done on computed tomography scans of each cadaver. Surgical guides were printed using direct metal laser sintering technology. Four zygomatic and two pterygoid implants were inserted in each case using the guided protocol and related tools. Post-operative computed tomography (CT) scans were obtained to evaluate deviations between the planned and inserted implants. Accuracy was measured by overlaying the real position in the post-operative CT on the virtual presurgical placement of the implant in a CT image. Descriptive and bivariate analyses of the data were performed. As a result, a total of 40 zygomatic and 20 pterygoid implants were inserted in 10 cadavers. The mean deviations between the planned and the placed zygomatic and pterygoid implants were respectively (mean +/- SD): 1.69 degrees +/- 1.12 degrees and 4.15 degrees +/- 3.53 degrees for angular deviation. Linear distance deviations: 0.93 mm +/- 1.23 mm and 1.35 mm +/- 1.45 mm at platform depth, 1.35 mm +/- 0.78 mm and 1.81 mm +/- 1.47 mm at apical plane, 1.07 mm +/- 1.47 mm and 1.22 mm +/- 1.44 mm for apical depth. In conclusion, the surgical guide system showed accuracy for all the variables studied and allowed acceptable and accurate implant placement regardless of the case complexity.

A novel guided zygomatic and pterygoid implant surgery system: a human cadaver study on accuracy / Grecchi, Francesco; Stefanelli, Luigi V; Grivetto, Fabrizio; Grecchi, Emma; Siev, Rami; Mazor, Ziv; Del Fabbro, Massimo; Pranno, Nicola; Franchina, Alessio; Di Lucia, Vittorio; De Angelis, Francesca; Goker, Funda. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH. - ISSN 1660-4601. - 18:11(2021). [10.3390/ijerph18116142]

A novel guided zygomatic and pterygoid implant surgery system: a human cadaver study on accuracy

Stefanelli, Luigi V
Secondo
;
Pranno, Nicola
;
De Angelis, Francesca
Penultimo
;
2021

Abstract

The aim of this human cadaver study was to assess the accuracy of zygomatic/pterygoid implant placement using custom-made bone-supported laser sintered titanium templates. For this purpose, pre-surgical planning was done on computed tomography scans of each cadaver. Surgical guides were printed using direct metal laser sintering technology. Four zygomatic and two pterygoid implants were inserted in each case using the guided protocol and related tools. Post-operative computed tomography (CT) scans were obtained to evaluate deviations between the planned and inserted implants. Accuracy was measured by overlaying the real position in the post-operative CT on the virtual presurgical placement of the implant in a CT image. Descriptive and bivariate analyses of the data were performed. As a result, a total of 40 zygomatic and 20 pterygoid implants were inserted in 10 cadavers. The mean deviations between the planned and the placed zygomatic and pterygoid implants were respectively (mean +/- SD): 1.69 degrees +/- 1.12 degrees and 4.15 degrees +/- 3.53 degrees for angular deviation. Linear distance deviations: 0.93 mm +/- 1.23 mm and 1.35 mm +/- 1.45 mm at platform depth, 1.35 mm +/- 0.78 mm and 1.81 mm +/- 1.47 mm at apical plane, 1.07 mm +/- 1.47 mm and 1.22 mm +/- 1.44 mm for apical depth. In conclusion, the surgical guide system showed accuracy for all the variables studied and allowed acceptable and accurate implant placement regardless of the case complexity.
2021
CAD/CAM; accuracy; computer aided implantology; dynamic navigation; guidance; guided surgery; navigation; pterygoid implants; surgical guides; surgical templates; zygomatic implant; cadaver; computer-aided design; humans; prostheses and implants; tomography, x-ray computed; surgery, computer-assisted
01 Pubblicazione su rivista::01a Articolo in rivista
A novel guided zygomatic and pterygoid implant surgery system: a human cadaver study on accuracy / Grecchi, Francesco; Stefanelli, Luigi V; Grivetto, Fabrizio; Grecchi, Emma; Siev, Rami; Mazor, Ziv; Del Fabbro, Massimo; Pranno, Nicola; Franchina, Alessio; Di Lucia, Vittorio; De Angelis, Francesca; Goker, Funda. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH. - ISSN 1660-4601. - 18:11(2021). [10.3390/ijerph18116142]
File allegati a questo prodotto
File Dimensione Formato  
Grecchi_A novel guided_2021.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 9.9 MB
Formato Adobe PDF
9.9 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1659688
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact