Among the Key Design Integration Issues (KDIIs) recently selected for the DEMOnstra-tion Fusion Power Plant (DEMO), the operation of the Balance of Plant (BoP) Power Conversion System (PCS) has been recognized as a crucial aspect, due to the typical pulsed regime characteriz-ing the fusion power plant. In the framework of the DEMO Water-Cooled Lead-Lithium Breeding Blanket (WCLL BB) concept, three BoP solutions have been recognized to be able to overcome this issue. They rely on different coupling options between the Primary Heat Transfer Systems (PHTSs) and the PCS: an Indirect Coupling Design (ICD) with Intermediate Heat Transport System (IHTS) and Energy Storage System (ESS), a Direct Coupling Design (DCD) with AUXiliary Boiler (AUXB), and a DCD with small ESS. The present paper deals with a preliminary feasibility assessment of the first two solutions. The analysis, carried out with the GateCycle™ code, referred to a preliminary design phase, devoted to the sizing of the main components, and to a second phase focused on the cycle optimization. The study demonstrated the feasibility of the two BoP concepts. They are able to produce a satisfactory average electric power (>700 MW) with an acceptable average net electric efficiency (33.6% for both concepts). For each solution, the main strengths and weaknesses are com-pared and discussed.
Analysis of EU-DEMO WCLL Power Conversion System in Two Relevant Balance of Plant Configurations: Direct Coupling with Auxiliary Boiler and Indirect Coupling / Narcisi, V.; Ciurluini, C.; Padula, G.; Giannetti, F.. - In: SUSTAINABILITY. - ISSN 2071-1050. - 14:10(2022), pp. 1-20. [10.3390/su14105779]
Analysis of EU-DEMO WCLL Power Conversion System in Two Relevant Balance of Plant Configurations: Direct Coupling with Auxiliary Boiler and Indirect Coupling
Narcisi V.Primo
;Ciurluini C.Secondo
;Giannetti F.
Ultimo
2022
Abstract
Among the Key Design Integration Issues (KDIIs) recently selected for the DEMOnstra-tion Fusion Power Plant (DEMO), the operation of the Balance of Plant (BoP) Power Conversion System (PCS) has been recognized as a crucial aspect, due to the typical pulsed regime characteriz-ing the fusion power plant. In the framework of the DEMO Water-Cooled Lead-Lithium Breeding Blanket (WCLL BB) concept, three BoP solutions have been recognized to be able to overcome this issue. They rely on different coupling options between the Primary Heat Transfer Systems (PHTSs) and the PCS: an Indirect Coupling Design (ICD) with Intermediate Heat Transport System (IHTS) and Energy Storage System (ESS), a Direct Coupling Design (DCD) with AUXiliary Boiler (AUXB), and a DCD with small ESS. The present paper deals with a preliminary feasibility assessment of the first two solutions. The analysis, carried out with the GateCycle™ code, referred to a preliminary design phase, devoted to the sizing of the main components, and to a second phase focused on the cycle optimization. The study demonstrated the feasibility of the two BoP concepts. They are able to produce a satisfactory average electric power (>700 MW) with an acceptable average net electric efficiency (33.6% for both concepts). For each solution, the main strengths and weaknesses are com-pared and discussed.File | Dimensione | Formato | |
---|---|---|---|
Narcisi_Analysis_2022.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
3.64 MB
Formato
Adobe PDF
|
3.64 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.