An uninterruptable wireless power supply is developed for a left ventricular assist device (LVAD), which is an implanted, electrically driven centrifugal pump used to treat advanced heart failure pathologies. The LVADs are currently powered through a cable driveline (DL) that exits the patient’s body through the skin. Here, an innovative uninterruptable power supply is presented, based on a hybrid wireless/wired architecture: the electric power of 10 W is transferred by the near field wireless power transfer technology operating at 300 kHz, from outside the human body to an implanted subcutaneous receiver, and then by an internal cable to the LVAD. A significant improvement of the subcutaneous receiver is here proposed, based on the integration in the receiving coil of a battery pack providing the following benefits: no-break power supply for the LVAD; peak load management; enhanced system reliability; elimination of DL infection; enhancement of patient’s quality of life. The proposed system is first designed and optimized, then a demonstrator is made and tested in a laboratory using the latest LVAD generation. The measured coil currents are used as sources for dosimetric analysis to assess the compliance of the system with the electromagnetic field safety and thermal regulations.

Uninterruptable Transcutaneous Wireless Power Supply for an {LVAD}: Experimental Validation and {EMF} Safety Analysis / Campi, Tommaso; Cruciani, Silvano; Maradei, Francescaromana; Montalto, Andrea; Musumeci, Francesco; Feliziani, Mauro. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - 63:5(2021), pp. 1717-1725. [10.1109/temc.2021.3102036]

Uninterruptable Transcutaneous Wireless Power Supply for an {LVAD}: Experimental Validation and {EMF} Safety Analysis

Tommaso Campi;Silvano Cruciani;Francesca Maradei;
2021

Abstract

An uninterruptable wireless power supply is developed for a left ventricular assist device (LVAD), which is an implanted, electrically driven centrifugal pump used to treat advanced heart failure pathologies. The LVADs are currently powered through a cable driveline (DL) that exits the patient’s body through the skin. Here, an innovative uninterruptable power supply is presented, based on a hybrid wireless/wired architecture: the electric power of 10 W is transferred by the near field wireless power transfer technology operating at 300 kHz, from outside the human body to an implanted subcutaneous receiver, and then by an internal cable to the LVAD. A significant improvement of the subcutaneous receiver is here proposed, based on the integration in the receiving coil of a battery pack providing the following benefits: no-break power supply for the LVAD; peak load management; enhanced system reliability; elimination of DL infection; enhancement of patient’s quality of life. The proposed system is first designed and optimized, then a demonstrator is made and tested in a laboratory using the latest LVAD generation. The measured coil currents are used as sources for dosimetric analysis to assess the compliance of the system with the electromagnetic field safety and thermal regulations.
2021
driveline infection (DLI); electromagnetic field (EMF) safety; heart failure; left ventricular assist device (LVAD); percutaneous driveline; transcutaneous energy transfer (TET); wireless power transfer (WPT)
01 Pubblicazione su rivista::01a Articolo in rivista
Uninterruptable Transcutaneous Wireless Power Supply for an {LVAD}: Experimental Validation and {EMF} Safety Analysis / Campi, Tommaso; Cruciani, Silvano; Maradei, Francescaromana; Montalto, Andrea; Musumeci, Francesco; Feliziani, Mauro. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - 63:5(2021), pp. 1717-1725. [10.1109/temc.2021.3102036]
File allegati a questo prodotto
File Dimensione Formato  
Campi_Uninterruptable_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.52 MB
Formato Adobe PDF
4.52 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1623965
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact