In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumor and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen, and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene [plastic scintillator (PS), CbHa] allowed to measure fragments production cross sections, exploiting a time-of-flight (ToF) technique. PS detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 degrees and 60 degrees with respect to the beam direction. The measured proton, deuteron, and triton differential production cross sections on C, O, and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.

Measurement of 12C Fragmentation cross sections on C, O, and H in the energy range of interest for particle therapy applications / Mattei, I.; Alexandrov, A.; Alunni Solestizi, L.; Ambrosi, G.; Argiro, S.; Bartosik, N.; Battistoni, G.; Belcari, N.; Biondi, S.; Bisogni, M. G.; Bruni, G.; Camarlinghi, N.; Carra, P.; Catanzani, E.; Ciarrocchi, E.; Cerello, P.; Clozza, A.; Colombi, S.; De Lellis, G.; Del Guerra, A.; De Simoni, M.; Di Crescenzo, A.; Donetti, M.; Dong, Y.; Durante, M.; Embriaco, A.; Emde, M.; Faccini, R.; Ferrero, V.; Ferroni, F.; Fiandrini, E.; Finck, C.; Fiorina, E.; Fischetti, M.; Francesconi, M.; Franchini, M.; Galli, L.; Gentile, V.; Hetzel, R.; Hild, S.; Iarocci, E.; Ionica, M.; Kanxheri, K.; Kraan, A. C.; Lante, V.; Lauria, A.; La Tessa, C.; Lopez Torres, E.; Massimi, C.; Marafini, M.; Mengarelli, A.; Mirabelli, R.; Montesi, M. C.; Morone, M. C.; Morrocchi, M.; Muraro, S.; Narici, L.; Pastore, A.; Pastrone, N.; Patera, V.; Pennazio, F.; Placidi, P.; Pullia, M.; Ramello, L.; Ridolfi, R.; Rosso, V.; Rovituso, M.; Sanelli, C.; Sartorelli, G.; Sato, O.; Savazzi, S.; Scavarda, L.; Schiavi, A.; Schuy, C.; Scifoni, E.; Sciubba, A.; Secher, A.; Selvi, M.; Servoli, L.; Silvestre, G.; Sitta, M.; Spighi, R.; Spiriti, E.; Sportelli, G.; Stahl, A.; Tomassini, S.; Tommasino, F.; Traini, G.; Toppi, M.; Valeri, T.; Valle, S. M.; Vanstalle, M.; Villa, M.; Weber, U.; Zoccoli, A.; Sarti, A.. - In: IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES. - ISSN 2469-7311. - 4:2(2020), pp. 269-282. [10.1109/TRPMS.2020.2972197]

Measurement of 12C Fragmentation cross sections on C, O, and H in the energy range of interest for particle therapy applications

Mattei, I.;Ciarrocchi, E.;De Simoni, M.;Faccini, R.;Ferroni, F.;Finck, C.;Franchini, M.;Iarocci, E.;Ionica, M.;Lauria, A.;Mirabelli, R.;Patera, V.;Rosso, V.;Sartorelli, G.;Schiavi, A.;Scifoni, E.;Sciubba, A.;Sportelli, G.;Toppi, M.;Valeri, T.;Sarti, A.
2020

Abstract

In a carbon ion treatment the nuclear fragmentation of both target and beam projectiles impacts on the dose released on the tumor and on the surrounding healthy tissues. Carbon ion fragmentation occurring inside the patient body has to be studied in order to take into account this contribution. These data are also important for the development of the range monitoring techniques with charged particles. The production of charged fragments generated by carbon ion beams of 115-353 MeV/u kinetic energy impinging on carbon, oxygen, and hydrogen targets has been measured at the CNAO particle therapy center (Pavia, Italy). The use of thin targets of graphite (C), PMMA (C2O5H8) and polyvinyl-toluene [plastic scintillator (PS), CbHa] allowed to measure fragments production cross sections, exploiting a time-of-flight (ToF) technique. PS detectors have been used to perform the ToF measurements, while LYSO crystals have been used for the deposited energy measurement and to perform particle identification. Cross sections have been measured at 90 degrees and 60 degrees with respect to the beam direction. The measured proton, deuteron, and triton differential production cross sections on C, O, and H, obtained exploiting the target subtraction strategy, are presented here as a function of the fragment kinetic energy.
2020
Radiation therapy clinical/preclinical evaluation/application studies; scintillators radiation detectors for medical applications; therapy imaging clinical/preclinical evaluation/application studies
01 Pubblicazione su rivista::01a Articolo in rivista
Measurement of 12C Fragmentation cross sections on C, O, and H in the energy range of interest for particle therapy applications / Mattei, I.; Alexandrov, A.; Alunni Solestizi, L.; Ambrosi, G.; Argiro, S.; Bartosik, N.; Battistoni, G.; Belcari, N.; Biondi, S.; Bisogni, M. G.; Bruni, G.; Camarlinghi, N.; Carra, P.; Catanzani, E.; Ciarrocchi, E.; Cerello, P.; Clozza, A.; Colombi, S.; De Lellis, G.; Del Guerra, A.; De Simoni, M.; Di Crescenzo, A.; Donetti, M.; Dong, Y.; Durante, M.; Embriaco, A.; Emde, M.; Faccini, R.; Ferrero, V.; Ferroni, F.; Fiandrini, E.; Finck, C.; Fiorina, E.; Fischetti, M.; Francesconi, M.; Franchini, M.; Galli, L.; Gentile, V.; Hetzel, R.; Hild, S.; Iarocci, E.; Ionica, M.; Kanxheri, K.; Kraan, A. C.; Lante, V.; Lauria, A.; La Tessa, C.; Lopez Torres, E.; Massimi, C.; Marafini, M.; Mengarelli, A.; Mirabelli, R.; Montesi, M. C.; Morone, M. C.; Morrocchi, M.; Muraro, S.; Narici, L.; Pastore, A.; Pastrone, N.; Patera, V.; Pennazio, F.; Placidi, P.; Pullia, M.; Ramello, L.; Ridolfi, R.; Rosso, V.; Rovituso, M.; Sanelli, C.; Sartorelli, G.; Sato, O.; Savazzi, S.; Scavarda, L.; Schiavi, A.; Schuy, C.; Scifoni, E.; Sciubba, A.; Secher, A.; Selvi, M.; Servoli, L.; Silvestre, G.; Sitta, M.; Spighi, R.; Spiriti, E.; Sportelli, G.; Stahl, A.; Tomassini, S.; Tommasino, F.; Traini, G.; Toppi, M.; Valeri, T.; Valle, S. M.; Vanstalle, M.; Villa, M.; Weber, U.; Zoccoli, A.; Sarti, A.. - In: IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES. - ISSN 2469-7311. - 4:2(2020), pp. 269-282. [10.1109/TRPMS.2020.2972197]
File allegati a questo prodotto
File Dimensione Formato  
Mattei_MeasurementOf12C_2020.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 7.81 MB
Formato Adobe PDF
7.81 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1571596
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact