Despite system thermal–hydraulic codes were extensively validated for transient simulations of LWR, several activities highlighted limited capabilities of these tools to model heat transfer within in-pool passive power removal system. Discrepancies with experimental results were related to the underestimate of pool boiling and film condensation heat transfer coefficients. Thus, the DIAEE of “Sapienza” University of Rome developed a modified version of RELAP5/Mod3.3, able to handle fundamental heat exchange phenomena involved in passive in-pool safety systems. A primary validation procedure has been performed for separated and integral effects. Dealing with nucleate boiling, the Root Mean Squared Relative Error (RMSRE) of wall superheat has been reduced from 1.290 to 0.182. Concerning film condensation, wall temperature RMSRE has been reduced from 0.192 to 0.058. The integral effect assessment has involved an experimental test of the PERSEO facility. The qualitative comparison between experiments and calculations has highlighted significant improvements of the modified RELAP5/Mod3.3.

Improvements of RELAP5/Mod3.3 heat transfer capabilities for simulation of in-pool passive power removal systems / Narcisi, V.; Melchiorri, L.; Giannetti, F.. - In: ANNALS OF NUCLEAR ENERGY. - ISSN 0306-4549. - 160:(2021), pp. 1-16. [10.1016/j.anucene.2021.108436]

Improvements of RELAP5/Mod3.3 heat transfer capabilities for simulation of in-pool passive power removal systems

Narcisi V.
Primo
;
Melchiorri L.
Secondo
;
Giannetti F.
Ultimo
2021

Abstract

Despite system thermal–hydraulic codes were extensively validated for transient simulations of LWR, several activities highlighted limited capabilities of these tools to model heat transfer within in-pool passive power removal system. Discrepancies with experimental results were related to the underestimate of pool boiling and film condensation heat transfer coefficients. Thus, the DIAEE of “Sapienza” University of Rome developed a modified version of RELAP5/Mod3.3, able to handle fundamental heat exchange phenomena involved in passive in-pool safety systems. A primary validation procedure has been performed for separated and integral effects. Dealing with nucleate boiling, the Root Mean Squared Relative Error (RMSRE) of wall superheat has been reduced from 1.290 to 0.182. Concerning film condensation, wall temperature RMSRE has been reduced from 0.192 to 0.058. The integral effect assessment has involved an experimental test of the PERSEO facility. The qualitative comparison between experiments and calculations has highlighted significant improvements of the modified RELAP5/Mod3.3.
2021
film condensation; heat transfer coefficient; nucleate boiling; PERSEO experiment; pool boiling; Safety system
01 Pubblicazione su rivista::01a Articolo in rivista
Improvements of RELAP5/Mod3.3 heat transfer capabilities for simulation of in-pool passive power removal systems / Narcisi, V.; Melchiorri, L.; Giannetti, F.. - In: ANNALS OF NUCLEAR ENERGY. - ISSN 0306-4549. - 160:(2021), pp. 1-16. [10.1016/j.anucene.2021.108436]
File allegati a questo prodotto
File Dimensione Formato  
Narcisi_Improvements_Post-print_2021.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 1.63 MB
Formato Adobe PDF
1.63 MB Adobe PDF
Narcisi_Improvements_2021.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.31 MB
Formato Adobe PDF
2.31 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1560956
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact