A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the contribution to the signal of the increased number of out-of-time interactions per beam crossing following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (2015–2018) demonstrate a substantial improvement in the energy resolution of the calorimeter over a range of energies extending from a few GeV to several tens of GeV.

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions / Sirunyan, A.M., Tumasyan, A., Adam, W., Ambrogi, F., Asilar, E., Bergauer, T., Brandstetter, J., Brondolin, E., Dragicevic, M., Ero, J., Escalante Del Valle, A., Flechl, M., Fruhwirth, R., Ghete, V.M., Hrubec, J., Jeitler, M., Krammer, N., Kratschmer, I., Liko, D., Madlener, T., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 15:10(2020), pp. P10002-P10002. [10.1088/1748-0221/15/10/P10002]

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

Del Re D.;Longo E.;Organtini G.;Paramatti R.;Rahatlou S.;Santanastasio F.;
2020

Abstract

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the contribution to the signal of the increased number of out-of-time interactions per beam crossing following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (2015–2018) demonstrate a substantial improvement in the energy resolution of the calorimeter over a range of energies extending from a few GeV to several tens of GeV.
2020
Calibration; Cluster finding; Fitting methods; Large detector-systems performance; Pattern recognition
01 Pubblicazione su rivista::01a Articolo in rivista
Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions / Sirunyan, A.M., Tumasyan, A., Adam, W., Ambrogi, F., Asilar, E., Bergauer, T., Brandstetter, J., Brondolin, E., Dragicevic, M., Ero, J., Escalante Del Valle, A., Flechl, M., Fruhwirth, R., Ghete, V.M., Hrubec, J., Jeitler, M., Krammer, N., Kratschmer, I., Liko, D., Madlener, T., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 15:10(2020), pp. P10002-P10002. [10.1088/1748-0221/15/10/P10002]
File allegati a questo prodotto
File Dimensione Formato  
Sirunyan_Reconstruction of signal_2020.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.09 MB
Formato Adobe PDF
2.09 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1495771
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 18
social impact