Abstract The Intensity Modulated Proton Linear Accelerator for Cancer Therapy (TOP-IMPLART) is under development and construction by ENEA in collaboration with the Italian Institute of Health (ISS) and the Oncological Hospital Regina Elena-IFO with financial support of Regione Lazio. Its peculiar time structure (few microseconds pulse width) and very high peak intensity (asymp 109 proton/pulse) demand for ad hoc dose delivery monitors (DDM). The TOP-IMPLART DDM is based on ionization gas chambers. One segmented chamber prototype uses Micro Pattern Gaseous Detector technology for the 2-dimensional simultaneous x/y readout; the charge collected from each active segment (strips with pad-like shape) is readout by a dedicated gain-adaptable electronics. Two small, highly sensitive, integral ionization chambers, using the same electronics, complement the 2D chamber for the monitor of the single pulse beam charge, down to 1 pC/pulse. While under development and deployment of its accelerating modular cavities, the linear TOP-IMPLART beam is improved thanks also to the continuous monitoring and characterization by these devices, whose responses are periodically compared to calibrated dosimetric detectors such as real-time active microDiamond sensor, passive Alanine pellets, intrinsically stable integral Faraday Cup. Different calibration campaigns have been recently conducted to measure the recombination and dose-rate effects on the above ionization chambers. The outcome of these measurements shows clear electron-ion recombination in the chamber active volume, largely related to the high beam intensity and its small transverse cross section. Those effects can be taken into account and used to correct the actual measurement of the DDM

Recombination effects in the ionization chambers dose delivery monitor of the TOP-IMPLART proton beam / Ampollini, A.; Basile, E.; Bazzano, G.; Cisbani, E.; De Angelis, C.; Della Monaca, S.; Ghio, F.; Giuliani, F.; Lucentini, M.; Nenzi, P.; Placido, C.; Picardi, L.; Ronsivalle, C.; Santavenere, F.; Spurio, A.; Surrenti, V.; Vadrucci, M.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1561:(2020), pp. 1-9. [10.1088/1742-6596/1561/1/012008]

Recombination effects in the ionization chambers dose delivery monitor of the TOP-IMPLART proton beam

Bazzano, G.;Placido, C.;
2020

Abstract

Abstract The Intensity Modulated Proton Linear Accelerator for Cancer Therapy (TOP-IMPLART) is under development and construction by ENEA in collaboration with the Italian Institute of Health (ISS) and the Oncological Hospital Regina Elena-IFO with financial support of Regione Lazio. Its peculiar time structure (few microseconds pulse width) and very high peak intensity (asymp 109 proton/pulse) demand for ad hoc dose delivery monitors (DDM). The TOP-IMPLART DDM is based on ionization gas chambers. One segmented chamber prototype uses Micro Pattern Gaseous Detector technology for the 2-dimensional simultaneous x/y readout; the charge collected from each active segment (strips with pad-like shape) is readout by a dedicated gain-adaptable electronics. Two small, highly sensitive, integral ionization chambers, using the same electronics, complement the 2D chamber for the monitor of the single pulse beam charge, down to 1 pC/pulse. While under development and deployment of its accelerating modular cavities, the linear TOP-IMPLART beam is improved thanks also to the continuous monitoring and characterization by these devices, whose responses are periodically compared to calibrated dosimetric detectors such as real-time active microDiamond sensor, passive Alanine pellets, intrinsically stable integral Faraday Cup. Different calibration campaigns have been recently conducted to measure the recombination and dose-rate effects on the above ionization chambers. The outcome of these measurements shows clear electron-ion recombination in the chamber active volume, largely related to the high beam intensity and its small transverse cross section. Those effects can be taken into account and used to correct the actual measurement of the DDM
2020
dosimetry; ionization chamber; proton
01 Pubblicazione su rivista::01a Articolo in rivista
Recombination effects in the ionization chambers dose delivery monitor of the TOP-IMPLART proton beam / Ampollini, A.; Basile, E.; Bazzano, G.; Cisbani, E.; De Angelis, C.; Della Monaca, S.; Ghio, F.; Giuliani, F.; Lucentini, M.; Nenzi, P.; Placido, C.; Picardi, L.; Ronsivalle, C.; Santavenere, F.; Spurio, A.; Surrenti, V.; Vadrucci, M.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 1561:(2020), pp. 1-9. [10.1088/1742-6596/1561/1/012008]
File allegati a questo prodotto
File Dimensione Formato  
Ampollini_Recombination_2020.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 6.12 MB
Formato Adobe PDF
6.12 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1419878
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact