Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nano- dosimetry, imaging, radiation protection and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics, that currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the pre-built, Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group / Arce, P; Bolst, D; Cutajar, D; Guatelli, S; Le, A; Rosenfeld, A B; Sakata, D; Bordage, M-C; Brown, J M C; Cirrone, P; Cuttone, G; Pandola, L; Petringa, G; Cortѐs-Giraldo, M A; Quesada, J M; Desorgher, L; Dondero, P; Mantero, A; Dotti, A; Wright, D H; Faddegon, B; Ramos-Mѐndez, J; Fedon, C; Incerti, S; Ivanchenko, V; Konstantinov, D; Latyshev, G; Kyriakou, I; Mancini-Terracciano, C; Maire, M; Novak, M; Omachi, C; Toshito, T; Perales, A; Perrot, Y; Romano, F; Sarmiento, L G; Sasaki, T; Sechopoulos, I; Simpson, E C. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 48:1(2021), pp. 19-56. [10.1002/mp.14226]

Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

Mancini-Terracciano, C;
2021

Abstract

Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nano- dosimetry, imaging, radiation protection and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics, that currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the pre-built, Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.
2021
Monte Carlo simulations; medical applications; radiotherapy, hadrotherapy
01 Pubblicazione su rivista::01a Articolo in rivista
Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group / Arce, P; Bolst, D; Cutajar, D; Guatelli, S; Le, A; Rosenfeld, A B; Sakata, D; Bordage, M-C; Brown, J M C; Cirrone, P; Cuttone, G; Pandola, L; Petringa, G; Cortѐs-Giraldo, M A; Quesada, J M; Desorgher, L; Dondero, P; Mantero, A; Dotti, A; Wright, D H; Faddegon, B; Ramos-Mѐndez, J; Fedon, C; Incerti, S; Ivanchenko, V; Konstantinov, D; Latyshev, G; Kyriakou, I; Mancini-Terracciano, C; Maire, M; Novak, M; Omachi, C; Toshito, T; Perales, A; Perrot, Y; Romano, F; Sarmiento, L G; Sasaki, T; Sechopoulos, I; Simpson, E C. - In: MEDICAL PHYSICS. - ISSN 0094-2405. - 48:1(2021), pp. 19-56. [10.1002/mp.14226]
File allegati a questo prodotto
File Dimensione Formato  
Arce_Report_2021.pdf

Open Access dal 13/12/2021

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.46 MB
Formato Adobe PDF
1.46 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1403060
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 120
  • ???jsp.display-item.citation.isi??? 118
social impact