Catheterization instruments are increasingly being improved to accurately diagnose and treat cardiovascular conditions. However, current catheter systems provide limited information about the shape of the catheter and tissue-instrument interaction forces during an intervention. Furthermore, relying on inconsistent feedback of such interaction forces during an intervention may result in tissue injury. This paper presents the first steps to estimate the interaction forces between a catheter and a mock-up arterial environment. We base the proposed method on a Pseudo-Rigid Body approximation of the catheter and integrate three-dimensional shape information provided by Fiber Bragg Grating sensors inside the catheter. The reconstructed forces along the catheter body can be fed back to the surgeon in visual and/or haptic form. In this work, the estimated forces are displayed in real-time in a graphical user interface with the reconstructed catheter shape. Experimental validation demonstrates a root mean square error of 0.03 N and a mean reconstruction error of 0.02 N.

Reconstructing endovascular catheter interaction forces in 3D using multicore optical shape sensors / Heunis, C. M.; Belfiore, V.; Vendittelli, M.; Misra, S.. - (2019), pp. 5419-5425. (Intervento presentato al convegno 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2019 tenutosi a Macau; China) [10.1109/IROS40897.2019.8968448].

Reconstructing endovascular catheter interaction forces in 3D using multicore optical shape sensors

Belfiore V.
;
Vendittelli M.
;
2019

Abstract

Catheterization instruments are increasingly being improved to accurately diagnose and treat cardiovascular conditions. However, current catheter systems provide limited information about the shape of the catheter and tissue-instrument interaction forces during an intervention. Furthermore, relying on inconsistent feedback of such interaction forces during an intervention may result in tissue injury. This paper presents the first steps to estimate the interaction forces between a catheter and a mock-up arterial environment. We base the proposed method on a Pseudo-Rigid Body approximation of the catheter and integrate three-dimensional shape information provided by Fiber Bragg Grating sensors inside the catheter. The reconstructed forces along the catheter body can be fed back to the surgeon in visual and/or haptic form. In this work, the estimated forces are displayed in real-time in a graphical user interface with the reconstructed catheter shape. Experimental validation demonstrates a root mean square error of 0.03 N and a mean reconstruction error of 0.02 N.
2019
2019 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2019
force and tactile sensing; simulation and animation; surgical robotics; steerable catheters/needles
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Reconstructing endovascular catheter interaction forces in 3D using multicore optical shape sensors / Heunis, C. M.; Belfiore, V.; Vendittelli, M.; Misra, S.. - (2019), pp. 5419-5425. (Intervento presentato al convegno 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems, IROS 2019 tenutosi a Macau; China) [10.1109/IROS40897.2019.8968448].
File allegati a questo prodotto
File Dimensione Formato  
Heunis_Reconstructing-endovascular _2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.48 MB
Formato Adobe PDF
2.48 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1387794
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact