CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay (0 νββ) of 100Mo. In this article, we detail the CUPID-Mo detector concept, assembly and installation in the Modane underground laboratory, providing results from the first datasets. The CUPID-Mo detector consists of an array of 20 100Mo -enriched 0.2 kg Li 2MoO 4 crystals operated as scintillating bolometers at ∼20mK. The Li 2MoO 4 crystals are complemented by 20 thin Ge optical bolometers to reject α events by the simultaneous detection of heat and scintillation light. We observe a good detector uniformity and an excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Light collection ensures the rejection of α particles at a level much higher than 99.9% – with equally high acceptance for γ/β events – in the region of interest for 100Mo 0 νββ. We present limits on the crystals’ radiopurity: ≤3μBq/kg of 226Ra and ≤2μBq/kg of 232Th. We discuss the science reach of CUPID-Mo, which can set the most stringent half-life limit on the 100Mo 0 νββ decay in half-a-year’s livetime. The achieved results show that CUPID-Mo is a successful demonstrator of the technology developed by the LUMINEU project and subsequently selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale bolometric 0 νββ experiment.

The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects / Armengaud, E., Augier, C., Barabash, A.S., Bellini, F., Benato, G., Benoit, A., Beretta, M., Berge, L., Billard, J., Borovlev, Y.A., Bourgeois, C., Briere, M., Brudanin, V.B., Camus, P., Cardani, L., Casali, N., Cazes, A., Chapellier, M., Charlieux, F., de Combarieu, M., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 80:1(2020). [10.1140/epjc/s10052-019-7578-6]

The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects

Bellini F.;Casali N.;
2020

Abstract

CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay (0 νββ) of 100Mo. In this article, we detail the CUPID-Mo detector concept, assembly and installation in the Modane underground laboratory, providing results from the first datasets. The CUPID-Mo detector consists of an array of 20 100Mo -enriched 0.2 kg Li 2MoO 4 crystals operated as scintillating bolometers at ∼20mK. The Li 2MoO 4 crystals are complemented by 20 thin Ge optical bolometers to reject α events by the simultaneous detection of heat and scintillation light. We observe a good detector uniformity and an excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Light collection ensures the rejection of α particles at a level much higher than 99.9% – with equally high acceptance for γ/β events – in the region of interest for 100Mo 0 νββ. We present limits on the crystals’ radiopurity: ≤3μBq/kg of 226Ra and ≤2μBq/kg of 232Th. We discuss the science reach of CUPID-Mo, which can set the most stringent half-life limit on the 100Mo 0 νββ decay in half-a-year’s livetime. The achieved results show that CUPID-Mo is a successful demonstrator of the technology developed by the LUMINEU project and subsequently selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale bolometric 0 νββ experiment.
2020
neutrinoless double beta decay; Majorana neutrino; cryogenic calorimeters
01 Pubblicazione su rivista::01a Articolo in rivista
The CUPID-Mo experiment for neutrinoless double-beta decay: performance and prospects / Armengaud, E., Augier, C., Barabash, A.S., Bellini, F., Benato, G., Benoit, A., Beretta, M., Berge, L., Billard, J., Borovlev, Y.A., Bourgeois, C., Briere, M., Brudanin, V.B., Camus, P., Cardani, L., Casali, N., Cazes, A., Chapellier, M., Charlieux, F., de Combarieu, M., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 80:1(2020). [10.1140/epjc/s10052-019-7578-6]
File allegati a questo prodotto
File Dimensione Formato  
Armengaud_CUPID-MoExperiment_2020.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.99 MB
Formato Adobe PDF
1.99 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1359506
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 98
  • ???jsp.display-item.citation.isi??? 89
social impact