The aim of this study was to evaluate the effectiveness of loading at 2 months after the surgical placement of implants. A tapered implant was used. Implant stability was determined using resonance frequency analysis at implant insertion (T0; primary stability), after 2 months (T1), and at the 6-month follow-up (T2). Descriptive statistics and the t-test were used. Significance was at P ≤ 0.05. A total of 268 implants were inserted in 142 patients. No patient dropped out and no implant had failed at the 6-month follow-up. The mean implant stability quotient value (ISQ) increased over time, with a statistically non-significant difference for T0 vs. T1 (P = 0.08) and a statistically significant difference for T1 vs. T2 (P = 0.0018) and T0 vs. T2 (P = 0.000). Only 99 implants, characterized by an extremely high mean primary stability value (80.34), did not have a recorded increase in ISQ at T1. A 2-month healing period allowed the implant to achieve secondary stability, confirming the effectiveness of the loading protocol at 2 months.

Is a two-month healing period long enough to achieve osseointegration? A prospective clinical cohort study / Cassetta, M.; Brandetti, G.; Altieri, F.. - In: INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0901-5027. - 49:5(2020), pp. 649-654. [10.1016/j.ijom.2019.10.020]

Is a two-month healing period long enough to achieve osseointegration? A prospective clinical cohort study

Cassetta M.
Primo
;
Altieri F.
Ultimo
2020

Abstract

The aim of this study was to evaluate the effectiveness of loading at 2 months after the surgical placement of implants. A tapered implant was used. Implant stability was determined using resonance frequency analysis at implant insertion (T0; primary stability), after 2 months (T1), and at the 6-month follow-up (T2). Descriptive statistics and the t-test were used. Significance was at P ≤ 0.05. A total of 268 implants were inserted in 142 patients. No patient dropped out and no implant had failed at the 6-month follow-up. The mean implant stability quotient value (ISQ) increased over time, with a statistically non-significant difference for T0 vs. T1 (P = 0.08) and a statistically significant difference for T1 vs. T2 (P = 0.0018) and T0 vs. T2 (P = 0.000). Only 99 implants, characterized by an extremely high mean primary stability value (80.34), did not have a recorded increase in ISQ at T1. A 2-month healing period allowed the implant to achieve secondary stability, confirming the effectiveness of the loading protocol at 2 months.
2020
loading protocol; osseointegration; primary stability; resonance frequency analysis; secondary stability
01 Pubblicazione su rivista::01a Articolo in rivista
Is a two-month healing period long enough to achieve osseointegration? A prospective clinical cohort study / Cassetta, M.; Brandetti, G.; Altieri, F.. - In: INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0901-5027. - 49:5(2020), pp. 649-654. [10.1016/j.ijom.2019.10.020]
File allegati a questo prodotto
File Dimensione Formato  
Cassetta_two-month_2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 824.78 kB
Formato Adobe PDF
824.78 kB Adobe PDF   Contatta l'autore
Cassetta_Is-a-two-month_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1338408
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact