Objective: To describe a very unique case of two Descemet stripping automated endothelial keratoplasty (DSAEK) surgeries performed in both eyes of the same patient with an extremely different graft thickness and overall corneal thickness but with the same corrected distance visual acuity (CDVA) 2 years after surgery. Case presentation: A 75-year-old woman with bilateral bullous keratopathy (BK) was submitted to DSAEK surgeries in both eyes, first in right and after 6 months in left eye. CDVA was 20/160 in the right eye and 20/63 in the left eye. Corneal thickness evaluated by anterior segment optical coherence tomography was 569 µm in the right eye and 560 µm in the left eye. The root mean square (RMS) was 2.1 in the right and left eyes. Endothelial cell densities were not detectable in both eyes. The estimated precut donor graft thickness from eye bank was 250 and 40 µm in the right and in the left graft, respectively. Two years after surgery CDVA was 20/25 in both eyes. Corneal thickness was 633 µm with a lenticule thickness of 206 µm in the right eye and 439 µm with a lenticule thickness of 48 µm in the left eye. The RMS was 1.7 in the right eye and 1.4 in the left eye. Endothelial cell density was 2.272 cells/mm2 in the right and 2.154 cells/mm2 in the left eye. Conclusion: DSAEK was safe and effective in the treatment of BK. In our report, the visual outcome resulted to be poorly related either to donor graft thickness or to postoperative corneal thickness.
Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient / Spadea, Leopoldo; Tonti, Emanuele; Napolitano, Rita. - In: INTERNATIONAL MEDICAL CASE REPORTS JOURNAL. - ISSN 1179-142X. - 12:(2019), pp. 55-59. [10.2147/IMCRJ.S192650]
Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
Spadea, Leopoldo
Primo
Supervision
;Tonti, EmanuelePenultimo
;Napolitano, RitaUltimo
2019
Abstract
Objective: To describe a very unique case of two Descemet stripping automated endothelial keratoplasty (DSAEK) surgeries performed in both eyes of the same patient with an extremely different graft thickness and overall corneal thickness but with the same corrected distance visual acuity (CDVA) 2 years after surgery. Case presentation: A 75-year-old woman with bilateral bullous keratopathy (BK) was submitted to DSAEK surgeries in both eyes, first in right and after 6 months in left eye. CDVA was 20/160 in the right eye and 20/63 in the left eye. Corneal thickness evaluated by anterior segment optical coherence tomography was 569 µm in the right eye and 560 µm in the left eye. The root mean square (RMS) was 2.1 in the right and left eyes. Endothelial cell densities were not detectable in both eyes. The estimated precut donor graft thickness from eye bank was 250 and 40 µm in the right and in the left graft, respectively. Two years after surgery CDVA was 20/25 in both eyes. Corneal thickness was 633 µm with a lenticule thickness of 206 µm in the right eye and 439 µm with a lenticule thickness of 48 µm in the left eye. The RMS was 1.7 in the right eye and 1.4 in the left eye. Endothelial cell density was 2.272 cells/mm2 in the right and 2.154 cells/mm2 in the left eye. Conclusion: DSAEK was safe and effective in the treatment of BK. In our report, the visual outcome resulted to be poorly related either to donor graft thickness or to postoperative corneal thickness.File | Dimensione | Formato | |
---|---|---|---|
Spadea_Different-graft_2019.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
1.84 MB
Formato
Adobe PDF
|
1.84 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.