A 3-year-old girl with Spinal Muscular Atrophy type I presented with a right pneumonia. On physical examination pulmonary auscultation revealed an asymmetry of breath sounds between the 2 hemithoraces, owing to decreased breath sounds in the right hemithorax. Blood tests were normal. The initial working diagnosis was a suspected area of mucus accumulation. A treatment with Free Aspire was started. Within a few days, the girl was discharged with a normal physical examination and X-ray study result. Spinal Muscular Atrophy is a rare neuromuscular disorder characterized by loss of motor neurons and progressive muscle wasting. Cough in these patients result ineffective. Free-Aspire is an electromedical machine for removing bronchoalveolar secretions. The case show that Free Aspire in patients with ineffective cough and impaired removal of secretions is a safe and effective device for the removal of bronchial secretions and could be an another help in the management of airway clearance.

Free-Aspire. A new device for the management of airways clearance in patient with ineffective cough / Bertelli, L.; Di Nardo, G.; Cazzato, S.; Ricci, G.; Pession, A.. - In: PEDIATRIC REPORTS. - ISSN 2036-7503. - 9:3(2017), pp. 53-54. [10.4081/pr.2017.7270]

Free-Aspire. A new device for the management of airways clearance in patient with ineffective cough

Di Nardo G.
Secondo
;
Cazzato S.;Pession A.
2017

Abstract

A 3-year-old girl with Spinal Muscular Atrophy type I presented with a right pneumonia. On physical examination pulmonary auscultation revealed an asymmetry of breath sounds between the 2 hemithoraces, owing to decreased breath sounds in the right hemithorax. Blood tests were normal. The initial working diagnosis was a suspected area of mucus accumulation. A treatment with Free Aspire was started. Within a few days, the girl was discharged with a normal physical examination and X-ray study result. Spinal Muscular Atrophy is a rare neuromuscular disorder characterized by loss of motor neurons and progressive muscle wasting. Cough in these patients result ineffective. Free-Aspire is an electromedical machine for removing bronchoalveolar secretions. The case show that Free Aspire in patients with ineffective cough and impaired removal of secretions is a safe and effective device for the removal of bronchial secretions and could be an another help in the management of airway clearance.
2017
free aspire; ineffective cough; pneumonia; spinal muscular atrophy
01 Pubblicazione su rivista::01i Case report
Free-Aspire. A new device for the management of airways clearance in patient with ineffective cough / Bertelli, L.; Di Nardo, G.; Cazzato, S.; Ricci, G.; Pession, A.. - In: PEDIATRIC REPORTS. - ISSN 2036-7503. - 9:3(2017), pp. 53-54. [10.4081/pr.2017.7270]
File allegati a questo prodotto
File Dimensione Formato  
Bertelli_Free-Aspire_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 549 kB
Formato Adobe PDF
549 kB Adobe PDF
Bertelli_Free-Aspire_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 88.59 kB
Formato Adobe PDF
88.59 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1300887
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact