The existence of a physiopathologic connection between nose and middle ear is widely accepted so that chronic purulent middle ear effusion (CPMEE) could be expected to be usually associated with nasal chronic disease or impaired function. Nevertheless such association is less frequently observed in clinical practice than one could expect, possibly because of inadequate nasal function evaluation. Thirty-five patients affected by CPMEE were included in this study in order to assess the incidence of nasal disorders. E.N.T. clinical history was obtained and E.N.T. physical examination, nasal endoscopy by fiberoptics, anterior rhinorheomanometry, non-specific nasal provocation test with histamine, mucoliary transport test, and allergic skin tests were performed. In the clinical history assessment 26 patients were affected by chronic rhinopathies, 16 by chronic pharyngitis, and 20 by frequent headache. At rhinoscopy we registered nasal septum deviation in 24 cases and mean and inferior turbinates hypertrophy in 31 cases. CPMEE and nasal septum deviation or turbinates hypertrophy were more frequently omolateral (p < .001 and p < .05, respectively). Total nasal resistance was 0.99 ± 0.49; it was abnormally high in 11 subjects bilaterally and in 4 subjects monolaterally and increased significantly in 32 patients following nasal provocation test. Mucociliary transport time was longer in CPMEE subjects than in 10 healthy subjects (18 ± 5 vs 13 ± 4 min; p < .05). Finally 10 patients presented positive skin tests. On the whole, 96% of non allergic patients included in this study showed signs of non-specific nasal hypersensitivity which could theoretically cause purulent middle ear effusion to chronicize. Indeed recurrent histamine release in response to specific and/or aspecific stimuli could cause the obstruction of the Eustachian tube and consequently inadequate middle ear ventilation.

Nasal hypersensitivity in purulent middle ear effusion / F., Filiaci; Masieri, Simonetta; Zambetti, Giampietro; Orlando, Maria Patrizia. - In: ALLERGOLOGIA ET IMMUNOPATHOLOGIA. - ISSN 0301-0546. - 25:2(1997), pp. 91-94.

Nasal hypersensitivity in purulent middle ear effusion

MASIERI, Simonetta;ZAMBETTI, Giampietro;ORLANDO, Maria Patrizia
1997

Abstract

The existence of a physiopathologic connection between nose and middle ear is widely accepted so that chronic purulent middle ear effusion (CPMEE) could be expected to be usually associated with nasal chronic disease or impaired function. Nevertheless such association is less frequently observed in clinical practice than one could expect, possibly because of inadequate nasal function evaluation. Thirty-five patients affected by CPMEE were included in this study in order to assess the incidence of nasal disorders. E.N.T. clinical history was obtained and E.N.T. physical examination, nasal endoscopy by fiberoptics, anterior rhinorheomanometry, non-specific nasal provocation test with histamine, mucoliary transport test, and allergic skin tests were performed. In the clinical history assessment 26 patients were affected by chronic rhinopathies, 16 by chronic pharyngitis, and 20 by frequent headache. At rhinoscopy we registered nasal septum deviation in 24 cases and mean and inferior turbinates hypertrophy in 31 cases. CPMEE and nasal septum deviation or turbinates hypertrophy were more frequently omolateral (p < .001 and p < .05, respectively). Total nasal resistance was 0.99 ± 0.49; it was abnormally high in 11 subjects bilaterally and in 4 subjects monolaterally and increased significantly in 32 patients following nasal provocation test. Mucociliary transport time was longer in CPMEE subjects than in 10 healthy subjects (18 ± 5 vs 13 ± 4 min; p < .05). Finally 10 patients presented positive skin tests. On the whole, 96% of non allergic patients included in this study showed signs of non-specific nasal hypersensitivity which could theoretically cause purulent middle ear effusion to chronicize. Indeed recurrent histamine release in response to specific and/or aspecific stimuli could cause the obstruction of the Eustachian tube and consequently inadequate middle ear ventilation.
1997
nasal hypersensitivity; nasal provocation test; purulent middle ear effusion
01 Pubblicazione su rivista::01a Articolo in rivista
Nasal hypersensitivity in purulent middle ear effusion / F., Filiaci; Masieri, Simonetta; Zambetti, Giampietro; Orlando, Maria Patrizia. - In: ALLERGOLOGIA ET IMMUNOPATHOLOGIA. - ISSN 0301-0546. - 25:2(1997), pp. 91-94.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/119877
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact