The conceptual design of the Primary Heat Transfer System (PHTS) of the water-cooled European (EU) DEMO foresees two independent cooling circuits, the breeding zone PHTS and the first wall PHTS. During the pulse time (120 minutes) the first delivers thermal power to the turbine, the latter delivers thermal power to the Intermediate Heat Transfer System (IHTS) equipped by an Energy Storage System (ESS). The IHTS delivers partially thermal power to the turbine in pulse so that to accumulate a suitable amount of energy in ESS to operate the turbine during the dwell time (10 minutes) at almost constant load, despite the EU DEMO pulsation of the generated thermal power. A dynamic model of the primary systems of water-cooled EU DEMO is developed using RELAP5/Mod3.3 system code to verify components sizing and to investigate code predictive capabilities. The model includes the primary and secondary side of the breeding zone and first wall, and in particular: in-vessel (i.e. breeding blanket) and ex-vessel components (i.e. main collectors, hot and cold legs, heat exchangers, steam generators, pumps). Preliminary assessments of the nodalization have been carried out, in particular checking pressure drops along the systems and heat exchanger performances.
Thermal-hydraulic modeling and analyses of the water-cooled EU DEMO using RELAP5 system code / Martelli, Emanuela; Giannetti, Fabio; Ciurluini, Cristiano; Caruso, Gianfranco; Del Nevo, Alessandro. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 146:(2019), pp. 1121-1125. [10.1016/j.fusengdes.2019.02.021]
Thermal-hydraulic modeling and analyses of the water-cooled EU DEMO using RELAP5 system code
Emanuela Martelli
;Fabio Giannetti;Cristiano Ciurluini;Gianfranco Caruso;
2019
Abstract
The conceptual design of the Primary Heat Transfer System (PHTS) of the water-cooled European (EU) DEMO foresees two independent cooling circuits, the breeding zone PHTS and the first wall PHTS. During the pulse time (120 minutes) the first delivers thermal power to the turbine, the latter delivers thermal power to the Intermediate Heat Transfer System (IHTS) equipped by an Energy Storage System (ESS). The IHTS delivers partially thermal power to the turbine in pulse so that to accumulate a suitable amount of energy in ESS to operate the turbine during the dwell time (10 minutes) at almost constant load, despite the EU DEMO pulsation of the generated thermal power. A dynamic model of the primary systems of water-cooled EU DEMO is developed using RELAP5/Mod3.3 system code to verify components sizing and to investigate code predictive capabilities. The model includes the primary and secondary side of the breeding zone and first wall, and in particular: in-vessel (i.e. breeding blanket) and ex-vessel components (i.e. main collectors, hot and cold legs, heat exchangers, steam generators, pumps). Preliminary assessments of the nodalization have been carried out, in particular checking pressure drops along the systems and heat exchanger performances.File | Dimensione | Formato | |
---|---|---|---|
Martelli_Thermal-hydraulic_2019.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.2 MB
Formato
Adobe PDF
|
1.2 MB | Adobe PDF | Contatta l'autore |
Martelli_Thermal-hydraulic modeling_postprint_2019.pdf
Open Access dal 02/10/2021
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Creative commons
Dimensione
449.92 kB
Formato
Adobe PDF
|
449.92 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.