This study is an investigation of the accuracy of reconstruction techniques for determining instantaneous fuel regression rate. Results of reconstruction techniques are compared with results obtained through the measurement of the pressure drop across the fuel in an Axial-Injection End-Burning hybrid rocket (EBHR). The results of numerous firing tests show that this method allows for the evaluation of the accuracy of the instantaneous fuel regression rates obtained by reconstruction techniques. The error bias of O/F values calculated by the reconstruction techniques were around ±10%, and were mainly caused by uncertainties in the measured values of oxidizer mass flowrate and the definition of firing duration. The instantaneous length of an EBHR-type fuel can be calculated from the measurement of the pressure drop across the fuel. However, the calculated fuel length history obtained by the pressure drop in a port does not coincide with that obtained by the reconstruction technique because of an underestimation in pressure drop.
The accuracy of reconstruction techniques for determining hybrid rocket fuel regression rate / Saito, Yuji; Kamps, Landon; Komizu, Kodai; Soeda, Kentaro; Bianchi, Daniele; Nasuti, Francesco; Nagata, Harunori. - 10:(2018), pp. 6418-6437. (Intervento presentato al convegno AIAA/SAE/ASEE Joint propulsion conference 2018. Held at the AIAA propulsion and energy forum 2018 tenutosi a Cincinnati, USA) [10.2514/6.2018-4923].
The accuracy of reconstruction techniques for determining hybrid rocket fuel regression rate
Daniele Bianchi;Francesco Nasuti;
2018
Abstract
This study is an investigation of the accuracy of reconstruction techniques for determining instantaneous fuel regression rate. Results of reconstruction techniques are compared with results obtained through the measurement of the pressure drop across the fuel in an Axial-Injection End-Burning hybrid rocket (EBHR). The results of numerous firing tests show that this method allows for the evaluation of the accuracy of the instantaneous fuel regression rates obtained by reconstruction techniques. The error bias of O/F values calculated by the reconstruction techniques were around ±10%, and were mainly caused by uncertainties in the measured values of oxidizer mass flowrate and the definition of firing duration. The instantaneous length of an EBHR-type fuel can be calculated from the measurement of the pressure drop across the fuel. However, the calculated fuel length history obtained by the pressure drop in a port does not coincide with that obtained by the reconstruction technique because of an underestimation in pressure drop.File | Dimensione | Formato | |
---|---|---|---|
Saito_the-accuracy-of_2018.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.62 MB
Formato
Adobe PDF
|
1.62 MB | Adobe PDF | Contatta l'autore |
Saito_frontespizio-indice_the-accuracy-of_2018.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
191.13 kB
Formato
Adobe PDF
|
191.13 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.