The aim of this report was to describe a new computer-guided technique for a controlled site preparation and palatal orthodontic miniscrew insertion using a dedicated software. A surgical guide was designed after planning the appropriate insertion sites on three-dimensional images created by the fusion of cone-beam computed tomography (CBCT) and digital dental model images. Pre- and postoperative CBCT images were compared and the angular, coronal, and apical deviations between the planned and the placed miniscrews were calculated. The mean coronal and apical deviations were 1.38 mm (range: 3.48–0.15 mm; standard deviation (SD): 0.65) and 1.73 mm (range: 5.41–0.10 mm; SD: 1.03), respectively, while the mean angular deviation was 4.60° (range: 15.23–0.54°; SD: 2.54). The present surgical guide allows a controlled and accurate palatal miniscrew placement in three dimensions.
Palatal orthodontic miniscrew insertion using a CAD-CAM surgical guide: description of a technique / Cassetta, M.; Altieri, F.; Di Giorgio, R.; Barbato, E.. - In: INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0901-5027. - ELETTRONICO. - (2018). [10.1016/j.ijom.2018.03.018]
Palatal orthodontic miniscrew insertion using a CAD-CAM surgical guide: description of a technique
Cassetta, M.
Primo
Investigation
;Altieri, F.Secondo
Investigation
;Di Giorgio, R.Penultimo
Supervision
;Barbato, E.Ultimo
Supervision
2018
Abstract
The aim of this report was to describe a new computer-guided technique for a controlled site preparation and palatal orthodontic miniscrew insertion using a dedicated software. A surgical guide was designed after planning the appropriate insertion sites on three-dimensional images created by the fusion of cone-beam computed tomography (CBCT) and digital dental model images. Pre- and postoperative CBCT images were compared and the angular, coronal, and apical deviations between the planned and the placed miniscrews were calculated. The mean coronal and apical deviations were 1.38 mm (range: 3.48–0.15 mm; standard deviation (SD): 0.65) and 1.73 mm (range: 5.41–0.10 mm; SD: 1.03), respectively, while the mean angular deviation was 4.60° (range: 15.23–0.54°; SD: 2.54). The present surgical guide allows a controlled and accurate palatal miniscrew placement in three dimensions.File | Dimensione | Formato | |
---|---|---|---|
Cassetta_Palatal_2018_inpress_1.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
475.24 kB
Formato
Adobe PDF
|
475.24 kB | Adobe PDF | Contatta l'autore |
Cassetta_Palatal_2018_inpress_2.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
504.82 kB
Formato
Adobe PDF
|
504.82 kB | Adobe PDF | Contatta l'autore |
Cassetta_Palatal_2018.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
979.31 kB
Formato
Adobe PDF
|
979.31 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.