BACKGROUND: Patients with cerebellar ataxia show increased upper body movements, which have an impact on balance and walking. AIM: In this study, we investigated the effect of using dynamic movement orthoses (DMO), designed as elastic suits, on trunk motion and gait parameters. DESIGN: Longitudinal uncontrolled study. SETTING: Outpatient rehabilitation unit. POPULATION: Eleven patients (7 men, 4 women; mean age: 49.9±9.5 years) with degenerative cerebellar ataxia were enrolled in this study. METHODS: Linear overground gait of patients was recorded by means of an optoelectronic gait analysis system before DMO use (DMO-) and during DMO use (DMO+). Time-distance parameters, lower limb joint kinematics, body sway, trunk oscillations, and gait variability (coefficient of variation [CV]) were recorded. Patient satisfaction with DMO device was measured using Quebec user evaluation of satisfaction with assistive technology. RESULTS: When using the DMO, patients showed a significant decrease in stance phase duration, double support phase duration, swing phase CV, pelvic range of motion (ROM), body sway, and trunk ROMs. A significant increase was observed in the swing phase duration and knee joint ROM. Out of 11 patients, 10 were either quite satisfied (8 points) or very satisfied (2 points) with the assistive device. CONCLUSIONS: The DMO reduce the upper body motion and in improve balance-related gait parameters. CLINICAL REHABILITATION IMPACT: We propose use of DMO as an assistive/rehabilitative device in the neurorehabilitation of cerebellar ataxia to improve the trunk control and gait stability. DMO may be considered a prototype that can be modified in terms of material characteristics, textile layers, elastic components, and diagonal and lateral seams.

Use of dynamic movement orthoses to improve gait stability and trunk control in ataxic patients / Serrao, Mariano; Casali, Carlo; Ranavolo, Alberto; Mari, Silvia; Conte, Carmela; Chini, Giorgia; Leonardi, Luca; Coppola, Gianluca; Di Lorenzo, Cherubino; Harfoush, Mahmoud; Padua, Luca; Pierelli, Francesco. - In: EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE. - ISSN 1973-9095. - 53:5(2017), pp. 735-743. [10.23736/S1973-9087.17.04480-X]

Use of dynamic movement orthoses to improve gait stability and trunk control in ataxic patients

Serrao, Mariano;Casali, Carlo;Ranavolo, Alberto;Mari, Silvia;Conte, Carmela;Chini, Giorgia;Leonardi, Luca;Coppola, Gianluca;Di Lorenzo, Cherubino;Pierelli, Francesco
2017

Abstract

BACKGROUND: Patients with cerebellar ataxia show increased upper body movements, which have an impact on balance and walking. AIM: In this study, we investigated the effect of using dynamic movement orthoses (DMO), designed as elastic suits, on trunk motion and gait parameters. DESIGN: Longitudinal uncontrolled study. SETTING: Outpatient rehabilitation unit. POPULATION: Eleven patients (7 men, 4 women; mean age: 49.9±9.5 years) with degenerative cerebellar ataxia were enrolled in this study. METHODS: Linear overground gait of patients was recorded by means of an optoelectronic gait analysis system before DMO use (DMO-) and during DMO use (DMO+). Time-distance parameters, lower limb joint kinematics, body sway, trunk oscillations, and gait variability (coefficient of variation [CV]) were recorded. Patient satisfaction with DMO device was measured using Quebec user evaluation of satisfaction with assistive technology. RESULTS: When using the DMO, patients showed a significant decrease in stance phase duration, double support phase duration, swing phase CV, pelvic range of motion (ROM), body sway, and trunk ROMs. A significant increase was observed in the swing phase duration and knee joint ROM. Out of 11 patients, 10 were either quite satisfied (8 points) or very satisfied (2 points) with the assistive device. CONCLUSIONS: The DMO reduce the upper body motion and in improve balance-related gait parameters. CLINICAL REHABILITATION IMPACT: We propose use of DMO as an assistive/rehabilitative device in the neurorehabilitation of cerebellar ataxia to improve the trunk control and gait stability. DMO may be considered a prototype that can be modified in terms of material characteristics, textile layers, elastic components, and diagonal and lateral seams.
2017
orthotic devices; rehabilitation; walking; postural balance; gait ataxia
01 Pubblicazione su rivista::01a Articolo in rivista
Use of dynamic movement orthoses to improve gait stability and trunk control in ataxic patients / Serrao, Mariano; Casali, Carlo; Ranavolo, Alberto; Mari, Silvia; Conte, Carmela; Chini, Giorgia; Leonardi, Luca; Coppola, Gianluca; Di Lorenzo, Cherubino; Harfoush, Mahmoud; Padua, Luca; Pierelli, Francesco. - In: EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE. - ISSN 1973-9095. - 53:5(2017), pp. 735-743. [10.23736/S1973-9087.17.04480-X]
File allegati a questo prodotto
File Dimensione Formato  
Serrao_Use-dynamic-movement_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 721.42 kB
Formato Adobe PDF
721.42 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1019499
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 14
social impact