For a variety of reasons, it is becoming an increasingly common requirement for ships to shut down ship generators and connect to high voltage shore power for as long as practicable while in port. Ship electrical equipment shall only be connected to shore supplies that are able to maintain harbor electrical distribution system voltage quality. Voltage drop, which is produced by the possible loading conditions of a ship when connected to a shore supply, may result in unsatisfactory operation of, and damage to, electrical and electronic equipment on board and thus, must be considered in the harbor distribution system design in order to comply with the requirements of international standards. A simple and fast method able to estimate the expected magnitude of voltage drops and provide information about the effectiveness of the various mitigation methods is essential. This paper presents the methodology and results for evaluation of the voltage drops of a practical harbor electrical distribution system with high voltage shore connection (HVSC). The potential voltage drops of the implemented HVSC are quantified using standard analytical formulas. Sensitivity analysis is performed to determine the critical parameters that significantly affect voltage drops. The parameters that have great improvement benefits should have high priority for implementation in other distribution systems with HVSC. The results obtained in this paper can provide engineers with useful information regarding the actual magnitude of voltage drops, as well as on the effectiveness of mitigation options for voltage drops, which would greatly enhance HV shore supply quality.

Voltage-drop calculations and power cable designs for harbor electrical distribution systems with high voltage shore connection / Chou, Min Hung; Su, Chun Lien; Lee, Yung Chi; Chin, Hai Ming; Parise, Giuseppe; Chavdarian, Peniamin. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 53:3(2017), pp. 1807-1814. [10.1109/TIA.2016.2646658]

Voltage-drop calculations and power cable designs for harbor electrical distribution systems with high voltage shore connection

PARISE, Giuseppe;
2017

Abstract

For a variety of reasons, it is becoming an increasingly common requirement for ships to shut down ship generators and connect to high voltage shore power for as long as practicable while in port. Ship electrical equipment shall only be connected to shore supplies that are able to maintain harbor electrical distribution system voltage quality. Voltage drop, which is produced by the possible loading conditions of a ship when connected to a shore supply, may result in unsatisfactory operation of, and damage to, electrical and electronic equipment on board and thus, must be considered in the harbor distribution system design in order to comply with the requirements of international standards. A simple and fast method able to estimate the expected magnitude of voltage drops and provide information about the effectiveness of the various mitigation methods is essential. This paper presents the methodology and results for evaluation of the voltage drops of a practical harbor electrical distribution system with high voltage shore connection (HVSC). The potential voltage drops of the implemented HVSC are quantified using standard analytical formulas. Sensitivity analysis is performed to determine the critical parameters that significantly affect voltage drops. The parameters that have great improvement benefits should have high priority for implementation in other distribution systems with HVSC. The results obtained in this paper can provide engineers with useful information regarding the actual magnitude of voltage drops, as well as on the effectiveness of mitigation options for voltage drops, which would greatly enhance HV shore supply quality.
2017
high voltage shore connection; marine vessel power system; supply quality; voltage drop
01 Pubblicazione su rivista::01a Articolo in rivista
Voltage-drop calculations and power cable designs for harbor electrical distribution systems with high voltage shore connection / Chou, Min Hung; Su, Chun Lien; Lee, Yung Chi; Chin, Hai Ming; Parise, Giuseppe; Chavdarian, Peniamin. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 53:3(2017), pp. 1807-1814. [10.1109/TIA.2016.2646658]
File allegati a questo prodotto
File Dimensione Formato  
Chou_Voltage-drop-calculations_postprint_2017.pdf

solo gestori archivio

Note: Articolo principale
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 968.96 kB
Formato Adobe PDF
968.96 kB Adobe PDF   Contatta l'autore
Chou_Voltage-drop-calculations_2017.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 740.29 kB
Formato Adobe PDF
740.29 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/976606
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 13
social impact